U-Turn Design Metatarsal Artery Flap

Author:

Reingrittha Pissanu,Kittipibul Krittin,Kulkittaya Somchai,Jitprapaikulsarn Surasak

Abstract

Background In distal forefoot defect, finding wound closure is challenging because of the distal site and small blood vessels involved. One possible resolution is the utilization of a metatarsal artery flap in a ‘U-turn’ design. This method offers several advantages, including its long length and a viable option for distal forefoot defect. Methods Thirty-six patients with forefoot injuries from metatarsophalangeal (MTP) joint to distal interphalangeal (DIP) joint due to trauma were consecutively recruited and completed the study. Outcomes were analyzed descriptively, and risk prediction modeling for edge necrosis was performed. Results The mean ± SD follow-up time was 27.3 months ±1.9. The median (IQR) MTP-to-DIP joint wound width and length were 1.8 (1.4, 3.0) and 3.2 cm (2.9, 6.2), respectively. The median (IQR) width, length, and width-to-length ratio flap dimensions were 3.6 (2.8, 6.0), 4.7 cm (4.3, 9.3), and 1.5 (1.2, 1.7), respectively. The mean ± SD operative time was 32.9 min ± 5.7. The median (IQR) intraoperative blood loss was 5.0 mL (4.0, 5.0). The mean ± SD hospital length of stay postoperatively was 4.0 days ±1.0. The mean ± SD Foot and Ankle Outcome Score and Foot Function Index were 64.1 ± 2.5 and 7.8% ± 3.3, respectively. All patients had good or excellent aesthetic satisfaction. Spontaneously resolving edge necrosis occurred in 13.9%. The mean ± SD time-to-start-ambulation was 1.7 weeks ±0.5. At the 2-year follow-up visit, all patients had reduced U-turn flap pivot point redundancy without shoe size impact, needing reoperation, or donor site morbidity. Edge necrosis was significantly associated with length-to-width ratio (P = 0.014) but not with Foot and Ankle Outcome Score or Foot Function Index. Conclusions Metatarsal artery flap of U-turn design was reliable and was associated with a short recovery time, alternative resolution for forefoot area due to short operation time, minimal blood loss, short hospital length of stay, and excellent availability.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3