Sterile Draping of Operative Microscopes in Breast Free Flaps and Surgical Site Infections

Author:

Marable Julian K.1ORCID,Spoer Daisy L.,Harish Varsha1,Berger Lauren E.,Song David H.2,Fan Kenneth L.2

Affiliation:

1. Georgetown University School of Medicine, Washington, DC

2. Department of Plastic and Reconstructive Surgery, MedStar Georgetown University Hospital, Washington, DC

Abstract

Background Operative microscopes are traditionally draped in single-use plastic to prevent infection theoretically. The necessity of this routine in breast free flap surgery is unclear. Alternatively, sterile wrapping of microscope handles would reduce operating room waste and provide a more cost-effective and environmentally sustainable approach to sterility. This study aimed to determine whether the draping technique used during abdominally based free flaps (Ab-FF) influenced the rate of surgical site infections. Methods We conducted a retrospective review of Ab-FF performed consecutively between March 2017 and August 2022. Patient demographics, comorbidities, perioperative data, and postoperative complications were collected. The primary outcomes included postoperative surgical site infections and environmental impact. Results Of the 281 identified breasts reconstructed with Ab-FF, operating microscopes were sterilely covered with microscope drapes (n = 215) or handle covers (n = 66) composed of polyethylene-based plastic. Overall, postoperative infections occurred in 9.3% of cases (n = 26) in either the recipient breast (n = 11, 3.9%) or abdominal donor site (n = 15, 5.3%), primarily due to S. aureus and Streptococcus species. The handle (n = 6, 9.1%) and drape (n = 20, 9.3%) cohorts had similar infection rates with no sequelae of operative complications. In multivariate analysis, radiation was the only independent predictor of postoperative infection, while bilateral reconstructions were independently protective. Replacing a microscope drape with a handle reduces carbon emissions by 1276 grams of CO2 and direct costs by $7.84 per item. Conclusions The principles of “Lean and Green” surgery prioritize reducing operating room generated waste to achieve financial and environmental sustainability. This cohort study of 281 breast free flaps demonstrates that switching from whole microscope draping to handle wrapping was not associated with an increased rate or odds of infection. Adopting a microscope handle wrapping protocol decreased the carbon footprint and operative costs. The results of this study offer evidence to support adoption and further exploration of pragmatic, cost-effective, and sustainable approaches to microsurgical breast reconstruction.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3