Nd:YAG laser capsulotomy rates in the Netherlands: practice variation and association with physician practice styles

Author:

Eggermont Rogier L.,Witteman Agnes M.,van Erkelens Judith A.ORCID,Vermeulen Karin,Vunderink Lydia,Reus Nicolaas J.ORCID

Abstract

Purpose:To determine the practice variation in the rate of Nd:YAG laser capsulotomy within 1 year after cataract surgery and to identify possible associations with physician practice styles.Setting:All hospitals and private clinics in the Netherlands.Design:Retrospective observational study.Methods:In the national medical claims database, we identified all laser capsulotomies performed in the Netherlands within a year after cataract surgery in the years 2016 and 2017. Centers with the lowest and highest percentages of Nd:YAG laser capsulotomies were interviewed on their physician practice styles related to the development of posterior capsule opacification.Results:The incidence of Nd:YAG laser capsulotomy varied between 1.2% and 26.0% in 2016 (median 5.0%) and between 0.9% and 22.7% in 2017 (median 5.0%). The rate of capsulotomy was highly consistent over time for each center (Pearson correlation coefficient, 0.89,P< .001). In general, ophthalmology centers with a high rate of Nd:YAG laser capsulotomy more often did not (routinely) polish the posterior lens capsule, performed cortex removal with coaxial irrigation/aspiration (I/A, instead of bimanual), and more often used hydrophilic intraocular lenses (IOLs) (compared with only using hydrophobic IOLs).Conclusions:We found a significant practice variation in performing Nd:YAG laser capsulotomy within 1 year after cataract surgery in the Netherlands. Routinely polishing the posterior capsule, using bimanual I/A, and the use of hydrophobic IOLs are associated with a lower incidence in Nd:YAG laser capsulotomy. Incorporating these practice styles may lower the practice variation and thus prevent added medical burden for the patient and decrease costs.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

Reference20 articles.

1. Posterior capsule opacification;Apple;Surv Ophthalmol,1992

2. Posterior capsule opacification severity, assessed with straylight measurement, as main indicator of early visual function deterioration;van Bree;Ophthalmology,2013

3. Complications of posterior capsulotomy with the Nd:YAG laser. Study of 226 cases [in French];Altamirano;Klin Monbl Augenheilkd,1994

4. An overview of Nd:YAG laser capsulotomy;Karahan;Med Hypothesis Discov Innov Ophthalmol,2014

5. Rate of retinal tear and detachment after neodymium:YAG capsulotomy;Wesolosky;J Cataract Refract Surg,2017