Size variability and fitting of 30-gauge thin-wall needles and 3-piece intraocular lens haptics for the flanged intrascleral fixation technique

Author:

Stunf Pukl Spela,Kronschläger MartinORCID,Ruiss ManuelORCID,Blouin StephaneORCID,Findl OliverORCID

Abstract

Purpose: To assess the diameter of different 30-gauge thin-wall needles and 3-piece intraocular lens (IOL) haptics readily used for the flanged-haptic intrascleral fixation technique. Setting: Hanusch Hospital, Vienna, Austria. Design: Laboratory investigation. Methods: 5 30-gauge thin-wall needles and 5 3-piece IOLs were assessed. An upright light microscopy was used for measurements. The inner and outer diameters of the needles and the end thickness of the haptics were analyzed and compared for haptic fitting into the needle. Results: Among the needles, the inner diameter of the T-lab needle was significantly wider compared with all the others (mean 209.3 ± 8.0 μm, P < .001), followed by TSK (194.8 ± 5.0 μm), MST (194.7 ± 5.8 μm), Sterimedix (187.5 ± 9.0 μm) and significantly narrower Meso-relle (mean 178.7 ± 7.0 μm, P < .05). The outer diameter of the T-lab needle was significantly larger of all (mean 316.0 ± 2.0 μm, P < .001). Concerning the IOLs, the AvanseePreset Kowa's haptic was significantly thinner (mean 127.2 ± 0.7 μm) than all the others, such as the TecnisZA900 Johnson & Johnson (143.5 ± 3.1 μm), the CTLucia202 Zeiss (143.8 ± 1.3 μm), and the AcrysofMA60AC Alcon (143.9 ± 1.4 μm). The only haptic that was thicker than all the others assessed was that of SensarAR40 Johnson & Johnson (170.7 ± 1.7 μm, P < .001). Conclusions: Most of the analyzed haptics would fit into most of the measured needles, with the exception of the Sensar AR40 in combination with the Meso-relle or Sterimedix needles. The combination of a larger needle lumen and a thinner haptic could result in more ease of insertion during surgery. If the dimensions of the needle and IOL haptics used are unknown, we recommend trying insertion before beginning surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

Reference10 articles.

1. Flanged intrascleral intraocular lens fixation with double-needle technique;Yamane;Ophthalmology,2017

2. Standardized flanged intrascleral intraocular lens fixation with the double-needle technique for cataract luxation in the vitreous chamber during phacoemulsification;Besozzi;J Ophthalmol,2021

3. Novel surgical technique of sutureless artificial iris and intraocular lens scleral fixation using Yamane technique;Muth;Am J Ophthalmol Case Rep,2022

4. Double-needle Yamane technique using flanged haptics in ocular trauma: a retrospective survey of visual outcomes and safety;Nowomiejska;J Clin Med,2021

5. Trailing-haptic-first modification of double-needle intrascleral haptic fixation technique;Kim;J Cataract Refract Surg,2018

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3