Comparative evaluation of multiple nomograms for predicting postoperative vault after implantable collamer lens surgery

Author:

Moshirfar MajidORCID,Han Kenneth D.,Jaafar Muhammed A.,Santos Jordan M.ORCID,Theis Joshua S.,Stoakes Isabella M.,Hoopes Philip C.ORCID

Abstract

Purpose: To compare the vault predictability of most available implantable collamer lens (ICL) sizing nomograms and identify which preoperative measurements are predictive of vault. Setting: Private practice in Draper, Utah. Design: Retrospective chart review. Methods: This study was a retrospective analysis of 209 eyes of 106 patients who underwent STAAR Surgical ICL implantation. Analyses were performed based on the availability of preoperative parameters, varying the number of eyes for each test. Mean absolute error (MAE) of predicted vs actual postoperative vault was calculated for each nomogram. The frequency of Kim, Rocamora (least absolute shrinkage and selection operator-optical coherence tomography), Russo, and Reinstein recommending the correct ICL size in instances when Parkhurst, optimized white-to-white (WTW), and STAAR could not recommend a definitive ICL size was determined. Univariate and multivariate linear regression analysis was performed between preoperative measurements and vault. Results: The Kim, Rocamora, Russo, and Reinstein nomograms had significantly lower MAE of predicted vs actual postoperative vault than the KSV2 and Nakamura V3 nomograms. The Russo formula most frequently recommended the correct ICL size when the Parkhurst, Optimized WTW, and STAAR nomograms could not provide ICL size recommendations. At the 0.05 significance level, anterior chamber depth (ACD), ciliary body inner diameter (CBID), and pupil diameter were the parameters found to have significant correlation with postoperative vault. Conclusions: The Kim, Rocamora, Russo, and Reinstein nomograms were the most predictive of vault. Additionally, ACD, CBID, and pupil diameter were found to be significantly correlated with vault and should be considered for use in future ICL sizing nomograms.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3