Accuracy comparison of tomography devices for ray tracing–based intraocular lens calculation

Author:

Wagner Felix M.ORCID,Hoffmann Peter,Preußner Paul-Rolf

Abstract

Purpose: To evaluate the interchangeability of different tomography devices used for ray tracing–based intraocular lens (IOL) calculation. Setting: Eye clinic, Castrop-Rauxel, Germany. Design: Retrospective analysis. Method: Measurements from 3 Placido-Scheimpflug devices and 3 optical coherence tomography (OCT) devices were compared in 83 and 161 other eyes after cataract surgery, respectively. 2-dimensional matrices of anterior local corneal curvature and local corneal thickness are transferred to the ray-tracing software OKULIX. Calculations are performed with the same IOL in the same position of an eye with the same axial length. Differences in spherical equivalent (SE), astigmatism, and spherical aberration are evaluated. Furthermore, the influence of the size of the matrices (optical zone) on the accuracy is quantified. Results: For the Placido-Scheimpflug devices, the deviations from the average of three measurements taken for each eye in SE (mean ± SD) were 0.17 ± 0.24 diopters (D), −0.26 ± 0.29 D, and 0.08 ± 0.39 D (P < .001, analysis of variance [ANOVA]), for the centroids of the astigmatic differences 0.04 D/173 degrees, 0.14 D/93 degrees, and 0.10 D/7 degrees, and for the median of the absolute values of the vector differences 0.31 D, 0.33 D, and 0.29 D. For OCT devices, the corresponding results were 0.01 ± 0.21 D, −0.03 ± 0.21 D, and 0.02 ± 0.20 D (P = .005, ANOVA); 0.18 D/120 degrees, 0.07 D/70 degrees, and 0.22 D/4 degrees; and 0.26 D, 0.30 D, and 0.33 D. The accuracy of the calculated spherical aberrations allows for an individual selection of the best fitting IOL model in most cases. Conclusions: The differences are small enough to make the devices interchangeable regarding astigmatism and spherical aberration. Although there are significant differences in SE between Scheimpflug and OCT devices, the differences between OCT devices are also small enough to make them interchangeable, but the differences between Placido-Scheimpflug devices are too large to make these devices interchangeable.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3