Comparison of intraocular lens power calculation formulas with and without total keratometry and ray tracing in patients with previous myopic SMILE

Author:

Meziane Elotmani AnouarORCID,Messerschmidt-Roth Anke,Nehme Alexandra,Müller Hans-Helge,Sekundo Walter

Abstract

Purpose: To evaluate the prediction error (PE) variance and absolute median PE of different intraocular lens (IOL) calculation formulas including last-generation formulas such as Barrett True-K with K, Okulix and total keratometry (TK)-based calculations with Haigis, and Barrett True-K in a simulation model in post–small-incision lenticule extraction (SMILE) eyes. Settings: Department of Ophthalmology, University Hospital Marburg, Marburg, Germany. Design: Prospective study. Methods: Preoperative measurements included IOL power calculation before and after SMILE surgery. The target refraction was set to be the lowest myopic refractive error in pre-SMILE eyes. The IOL power targeting at the lowest myopic refractive error in pre-SMILE eyes was selected for the post-SMILE IOL calculation of the same eye. The difference between the predicted refraction of pre- and post-SMILE eyes with the same IOL power was defined as IOL difference. The refractive change induced by SMILE was defined as the difference between preoperative and postoperative manifest refraction. Results: 98 eyes from 49 patients underwent bilateral myopic SMILE. The PE variance of Okulix was not significantly different compared with Barrett True-K with TK (P = .471). The SDs of the mean PEs were ±0.413 D (Haigis-TK), ±0.453 D (Okulix), ±0.471 D (Barrett True-K with TK), ±0.556 D (Haigis-L), and ±0.576 D (Barrett True-K with K). The mean absolute PE was 0.340 D, 0.353 D, 0.404 D, 0.511 D, and 0.715 D for Haigis-TK, Okulix, Barrett True-K with TK, Barrett True-K with K, and Haigis-L, respectively. The highest percentage of eyes within ±0.50 D was achieved by Okulix, followed by Haigis-TK, Barrett True-K with TK, Barrett True-K with K, and Haigis-L. Conclusions: Results suggest that Haigis in combination with TK, Okulix, and Barrett True-K with and without TK offer good options for accurate IOL power calculation after SMILE. Haigis-L showed a tendency for myopic shift in eyes after previous SMILE.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3