Long-term results of a new posterior chamber phakic intraocular lens in patients with high myopia: 5-year results

Author:

Cakir IhsanORCID,Sonmez OrcunORCID,Pehlivanoglu Seren,Cakir Gulay YalcinkayaORCID,Yildiz Burcin KepezORCID,Yildirim YusufORCID,Agca AlperORCID

Abstract

Purpose: To evaluate the long-term refractive outcomes of Eyecryl posterior chamber spherical phakic intraocular lens (pIOL) implantation in high myopia and endothelial cell density (ECD) change. Setting: Beyoglu Eye Training and Research Hospital, Istanbul, Turkey. Design: Retrospective. Methods: Eyes that were not suitable for corneal refractive surgery, had high myopia between −6.00 diopters (D) and −20.00 D, had Eyecryl posterior chamber spherical pIOL implantation, and had at least 5 years of follow-up were included. Preoperative ECD was ≥2300 cells/mm2 and cylindrical value was ≤2.0 D in all cases. Preoperative and postoperative first, third, and fifth years of refraction, uncorrected and corrected distance visual acuity (UDVA/CDVA), and ECD were recorded. Results: 36 eyes of 18 patients were examined. The mean UDVA and CDVA in postoperative fifth years were 0.24 ± 0.19 logMAR and 0.12 ± 0.18 logMAR, respectively. The safety and efficacy indices were 1.52 ± 0.54 and 1.14 ± 0.38, respectively. At 5 years, the spherical equivalent was ±0.50 D in 75% of eyes and ±1.00 D in 92% of eyes. After 5 years, the mean cumulative ECD loss was 6.91% (P = .07). The annual ECD loss was 1.57% in the first year, 0.26% between 1 year and 3 years, and 2.38% between 3 years and 5 years. Asymptomatic anterior capsule opacity developed in 1 eye 4 years after surgery. Rhegmatogenous retinal detachment developed in 1, and myopic choroidal neovascular membrane occurred in 1 eye. Conclusions: Eyecryl posterior chamber spherical pIOL implantation is one of the effective and safe refractive surgical methods in correcting high myopia with predictable and stable refractive results over a 5-year period. Longer-term studies are needed for complications such as decreased ECD, retinal complications, and lens opacity.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3