Clinical performance of a hybrid presbyopia-correcting intraocular lens in patients undergoing cataract surgery in a multicenter trial

Author:

Chang Daniel H.,Hu Jerry G.ORCID,Lehmann Robert P.,Thompson Vance M.,Tsai Linda H.,Thomas Eugenia K.

Abstract

Purpose: To compare the clinical performance of TECNIS Synergy intraocular lens (IOL), model ZFR00V, vs TECNIS IOL, model ZCB00, in cataract patients. Setting: Multicenter clinical setting. Design: Prospective, randomized, subject/evaluator-masked clinical trial. Methods: Cataract patients aged ≥22 years were randomly assigned 1:1 to bilateral implantation with ZFR00V or ZCB00. Key end points at 6 months postsurgery included monocular and binocular visual acuities at 4 m, 66 cm, 33 cm, and/or 40 cm, binocular distance-corrected defocus testing, patient-reported outcomes, and safety. Results: 272 patients were implanted with ZFR00V (135) or ZCB00 (137). At 6 months, 83/131 (63.4%) ZFR00V patients demonstrated 20/25 or better combined monocular distance-corrected vision at far, intermediate, or near, compared with 5/130 (3.8%) ZCB00 patients. ZFR00V demonstrated excellent binocular uncorrected vision at intermediate (0.022 logMAR) and distance-corrected vision at 40 cm (0.047 logMAR). Strong ZFR00V performance persisted under mesopic conditions (0.244 logMAR or ∼20/32 Snellen), where improvement over ZCB00 with distance-corrected vision at near was 3.5 lines. ZFR00V provided a broad range of functional vision (20/32 or better) through −3.5 diopters of defocus (29 cm). Most ZFR00V patients reported no spectacle wear overall (93.1%) or at all 4 viewing distances combined (87.8%), and 55.7% qualified as completely spectacle independent. Relatively low proportions of ZFR00V patients reported being very/extremely bothered by halos (13.7%), starbursts (11.5%), or night glare (8.4%). The safety profile was similar between IOL groups. Conclusions: TECNIS Synergy ZFR00V demonstrated improved intermediate and near vision, increased range of vision, and greater spectacle independence vs TECNIS monofocal ZCB00.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3