Abstract
Purpose:
To evaluate computationally the optical performance of AcrySof IQ Vivity extended depth-of-focus (EDOF) intraocular lenses (IOLs) in post–laser in situ keratomileusis (LASIK) eyes.
Setting:
Visual Optics and Biophotonics Laboratory, Madrid, Spain.
Design:
Experimental study.
Methods:
Computer pseudophakic eye models were implemented using reported post-LASIK corneal aberrations (refractive corrections from −7.5 to +4.5 diopters [D]) and virtually implanted with monofocal (AcrySof IQ) or EDOF (AcrySof IQ Vivity) IOLs. Retinal image quality was quantified through visual Strehl (VS). The depth of focus (DOF) was calculated from the through-focus VS curves. Halos were estimated from the light spread in the image of a pinhole. Those quantitative parameters were obtained for 5.0 and 3.0 mm pupil diameters.
Results:
Simulated virgin eyes showed VS of 0.89/0.99 with monofocal IOLs and 0.74/0.52 with EDOF IOLs for 5.0/3.0 mm pupils at best focus. VS decreased with induced spherical aberration (SA) by 25% and with induced SA + coma by 61% on average (3.0 mm pupils). The DOF was 2.50 D in virgin eyes with EDOF IOLs, 1.66 ± 0.30 and 2.54 ± 0.31 D (P < .05) on average in post-LASIK eyes for 3.0 mm pupils, monofocal and EDOF IOLs, respectively. Halos were more sensitive to SA induction for 5.0 mm pupils, and induction of positive SA (myopic LASIK) resulted in reduced halos with the EDOF when compared with the monofocal IOLs, by 1.62 (SA) and 1.86 arc min (SA + coma), on average.
Conclusions:
Computer post-LASIK pseudophakic eye models showed that the DOF was less dependent on the presence of SA and coma with EDOF IOLs and that halos were reduced with EDOF IOLs compared with the monofocal IOL for a range of SA.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Sensory Systems,Ophthalmology,Surgery
Reference31 articles.
1. The history of LASIK;Reinstein;J Refract Surg,2012
2. Photorefractive keratectomy: a technique for laser refractive surgery;Munnerlyn;J Cataract Refract Surg,1988
3. Optical response to LASIK surgery for myopia from total and corneal aberration measurements;Marcos;Invest Ophthalmol Vis Sci,2001
4. Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia;Llorente;J Refract Surg,2004
5. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing;Moreno-Barriuso;Invest Ophthalmol Vis Sci,2001
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献