New simulation software to predict postoperative corneal stiffness before laser vision correction

Author:

Francis Mathew,Shetty Rohit,Padmanabhan Prema,Vinciguerra Riccardo,Vinciguerra Paolo,Lippera Myrta,Matalia Himanshu,Khamar PoojaORCID,Chinnappaiah NandiniORCID,Mukundan Deepa,Nuijts Rudy M.M.A.ORCID,Sinha Roy Abhijit

Abstract

Purpose: To develop a new virtual surgery simulation platform to predict postoperative corneal stiffness (Kcmean) after laser vision correction (LVC) surgery. Setting: Narayana Nethralaya Eye Hospital and Sankara Nethralaya, India; Humanitas Clinical and Research Center, Italy. Design: Retrospective observational case series. Methods: 529 eyes from 529 patients from 3 eye centers and 10 post–small-incision lenticule extraction (SMILE) ectasia eyes were included. The software (called AcuSimX) derived the anisotropic, fibril, and extracellular matrix biomechanical properties (using finite element calculation) of the cornea using the preoperative Corvis-ST, Pentacam measurement, and inverse finite element method assuming published healthy collagen fibril orientations. Then, the software-computed postoperative Kcmean was adjusted with an artificial intelligence (AI) model (Orange AI) for measurement uncertainties. A decision tree was developed to classify ectasia from normal eyes using the software-computed and preoperative parameters. Results: In the training cohort (n = 371 eyes from 371 patients), the mean absolute error and intraclass correlation coefficient were 6.24 N/m and 0.84 (95% CI, 0.80-0.87), respectively. Similarly, in the test cohort (n = 158 eyes from 158 patients), these were 6.47 N/m and 0.84 (0.78-0.89), respectively. In the 10 ectasia eyes, the measured in vivo (74.01 [70.01-78.01]) and software-computed (74.1 [69.03-79.17]) Kcmean were not statistically different (P = .96). Although no statistically significant differences in these values were observed between the stable and ectasia groups (P ≥ .14), the decision tree classification had an area under the receiver operating characteristic curve of 1.0. Conclusions: The new software provided an easy-to-use virtual surgery simulation platform for post-LVC corneal stiffness prediction by clinicians and was assessed in post-SMILE ectasia eyes. Further assessments with ectasia after surgeries are required.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Artificial intelligence-aided diagnosis and treatment in the field of optometry;International Journal of Ophthalmology;2023-09-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3