Comparative study of FLACS vs conventional phacoemulsification for cataract patients with high myopia

Author:

Zhao Lijuan1,Tan Mengjia1ORCID,Zhang Junfang1,Hao Mengyao2,Liang Shu1,Ji Min1,Guan Huaijin1ORCID

Affiliation:

1. : the Eye Institute, Affiliated Hospital of Nantong University, Nantong, China.

2. :Yixing people’ s hospital ,Wuxi, China

Abstract

Purpose: To compare the short-term changes in cornea, retina and choroid of femtosecond laser-assisted cataract surgery (FLACS) with conventional phacoemulsification (CPS) in high myopia patients with cataract. Setting: Affiliated Hospital of Nantong University, Jiangsu Province, China. Design: Prospective single-center study. Method: Demographics, ocular clinical features, ultrasound power, absolute phacoemulsification time, and effective phacoemulsification time were recorded for each patient. Endothelial cell density (ECD), central corneal thickness (CCT), best corrected distance visual acuity (CDVA), intraocular pressure(IOP), center foveal thickness(CFT), subfoveal choroidal thickness (SFCT) and choroidal vascularity index (CVI) were evaluated preoperatively and at 1 week, 1 month, and 3months postoperatively. Intraoperative parameters and intraoperative /postoperative complications were recorded. Results: Ninety-seven eyes (46 eyes and 51 eyes in the FLACS and CPS groups, respectively) were included and analyzed. Cumulative dissipated energy was lower in FLACS group compared with CPS group (P <0.05). The increase in CCT was significantly lower in the FLACS group compared with the CPS group at 1week and 1month (P <0.05). CDVA and IOP were similar in both groups at the final visit (P > 0.05). The ECD decreased was lower among CPS patients compare with FLACS patients. CFT, SFCT and CVI increase in both groups but were increase more in CPS group with high myopia patients. No serious complications occurred in either group. Conclusions: FLACS is a more safety and effective in cataract patients with high myopia. It has advantages in effectively reducing EPT and promoting faster recovery of the cornea, macular and choroidal thickness.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference35 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3