Systematic and objective wet-lab testing of instruments for phacoemulsification: new Formalin Quadrant Model

Author:

Giger-Lange ChristinaORCID,Rattenbacher-Kiser KarinORCID,Di Lanzo Jessica,Di Nardo Silvio,Menapace Rupert,Ille FabianORCID

Abstract

Purpose: To validate an improved wet-lab model for systematic and objective efficiency testing of instruments for phacoemulsification. Setting: Institute of Medical Engineering, Lucerne University of Applied Sciences and Arts, Lucerne, Switzerland. Design: Experimental study. Methods: Porcine lenses were incubated for different time spans in formalin to simulate different cataract densities. Lenses were cut in quadrants and emulsified in a silicone test chamber. The use of ultrasound was restricted to full occlusion and the minimal power needed to promote emulsification. Equivalence to the surgical situation and cataract consistency were judged by an experienced surgeon. Efficiency was rated by effective phacoemulsification time, liquid consumption, and total surgery time. Results: Formalin incubation times of 2 hours, 1.25 hours, and 0.5 hours were validated for hard, middle-hard, and soft cataracts, respectively. Systematic testing of different fluidics settings revealed the unique opportunities of the improved model: Experiments could be performed by laboratory staff without any surgical experience after a short training, and the model provided results in a fast and reproducible manner. Reduced effective phacoemulsification time, shorter total surgery time, and less liquid consumption were observed with higher fluidics settings, confirming and complementing earlier clinical findings. Conclusions: The Formalin Quadrant Model can be used to test new designs of instrumentation on different cataract densities or various instrument settings for efficiency. Using a validated cataract substitute, it closely represents the clinical situation and thus renders valid results in a short time. Instruments can be tested and improved profoundly before costly and elaborate clinical trials have to be applied.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3