Characterizing glare effects associated with diffractive optics in presbyopia-correcting intraocular lenses

Author:

Łabuz Grzegorz1,Khoramnia Ramin1ORCID,Yan Weijia1,van den Berg Thomas JTP2ORCID,Auffarth Gerd U.1ORCID,Naujokaitis Tadas1ORCID,Tandogan Tamer13

Affiliation:

1. The David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, INF 400, 69120 Heidelberg, Germany.

2. Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, the Netherlands

3. Augenklinik Pallas, 4600 Olten, Switzerland

Abstract

Purpose: To objectively quantify glare of intraocular lenses (IOLs) utilizing a diffractive principle to extend visual range. To identify models with increased susceptibility to inducing glare. Setting: David J Apple Laboratory, Heidelberg, Germany. Design: Laboratory investigation. Methods: Glare was assessed by means of straylight parameter with a standard C-Quant (Oculus GmbH) intended for 7°. In addition, two C-Quant modifications were used to test lower angles (i.e., 2.5° and 3.5°). The following IOL models were assessed: PanOptix (Alcon Inc.) and AT Lisa Tri (Zeiss Meditec), Synergy (J&J Vision), and Triumf (BVI Medical), the latter two with chromatic-aberration correction at distance. Straylight from trifocals was compared against a monofocal W-60R lens (Santen). The C-Quant test was performed through the studied IOLs via additional optical components attached to its ocular. Results: Straylight (deg2sr-1) of the control was <1 at all tested angles, with the trifocal models showing comparable straylight at 7°. At 3.5°, Triumf’s straylight increased to 15.5 ±0.6, followed by Synergy (6.2 ±1.1), PanOptix (4.1 ±0.3), and AT Lisa Tri (2.0 ±0.8). The chromatic-aberration correcting models demonstrated correspondingly high straylight (Synergy: 18.8 ±1.3; Triumf: 17.3 ±0.5) at 2.5° compared to PanOptix (4.3 ±0.4), AT Lisa Tri (2.1 ±0.1) and monofocal IOLs yielding minimal or no increase. Conclusions: Trifocal IOLs induced increased straylight, but it was limited to lower angles, which may cause difficulties detecting these effects using a standard clinical approach. The latest IOL designs featuring chromatic aberration correction at far-focus appear more susceptible than the established trifocals to inducing glare phenomena.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference35 articles.

1. History of ocular straylight measurement: a review;van den Berg;Z Med Phys,2013

2. Report on disability glare;Vos;CIE Collect,1999

3. Straylight effects with aging and lens extraction;Van Den Berg;Am J Ophthalmol,2007

4. Ocular straylight in the normal pseudophakic eye;Łabuz;J Cataract Refract Surg,2015

5. Effect of neodymium: YAG laser capsulotomy on retinal straylight values in patients with posterior capsule opacification;van Bree;J Cataract Refract Surg,2008

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Refractive Lens Exchange: A Review;Klinische Monatsblätter für Augenheilkunde;2024-08

2. Übersicht über Intraokularlinsen mit Presbyopie-korrigierenden Optiken;Die Ophthalmologie;2024-07-09

3. Optische Bank-Evaluierung für spezielle Intraokularlinsenoptiken;Die Ophthalmologie;2024-07-08

4. Presbyopiekorrektur mit multifokalen Intraokularlinsen;Springer Reference Medizin;2024

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3