Teleglaucoma Using a New Smartphone-Based Tool for Visual Field Assessment

Author:

Grau Elisabeth1ORCID,Andrae Stefan1,Horn Folkert1,Hohberger Bettina1,Ring Matthias2,Michelson Georg13

Affiliation:

1. Department of Ophthalmology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg

2. Department of Computer Science, Machine Learning and Data Analytics Lab, Friedrich-Alexander-University Erlangen-Nürnberg (FAU)

3. Talkingeyes and More GmbH, Henkestraße, Erlangen, Germany

Abstract

Précis: COVID-19 underlines the importance of telemedical diagnostics. The smartphone-based campimetry (Sb-C) is a newly developed digital application allowing visual field testing using a head-mounted device and a smartphone. It enables visual field screening remotely from a clinic. Background: Sb-C is a newly developed tool for functional ophthalmic diagnosis. This study aimed to examine the comparability of the Sb-C and Octopus 900 to ensure ophthalmological care in times of social distancing. Methods: Total 93 eyes were included in the study. After an ophthalmological examination, the visual field was tested by the Octopus program G1 and by the smartphone-based campimeter. The Sb-C was performed using VR glasses and an iPhone 6. The software Sb-C was downloaded and installed as SmartCampiTracker app and is examining the 30-degree visual field with 59 test positions corresponding to the G pattern of Octopus G1. Sensitivities were recorded and saved on the app. In addition, test-retest reliability was tested on 6 ophthalmologically healthy participants. Results: The group comprised 48 women and 45 men (mean age: 62.52±12.2 y) including 19 controls, 17 patients with ocular hypertension, 11 preperimetric glaucomas, and 46 perimetric glaucomas. The mean sensitivity (MS) of all points of G1 perimetry was 23.13 dB (95% CI, 22.08–24.18). The MS of the Sb-C was 21.23 dB (95% CI, 20.37–22.08). The correlation between the mean MS measured by G1 perimetry and the Sb-C was strong (r=0.815, P<0.05). The test-retest reliability showed a correlation of r=0.591 (P<0.05). Conclusions: With some technical adjustments, the Sb-C shows promise for screening glaucoma and monitoring disease progression remotely from an ophthalmologic clinic.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3