Artificial Intelligence to Assess Tracheal Tubes and Central Venous Catheters in Chest Radiographs Using an Algorithmic Approach With Adjustable Positioning Definitions

Author:

Rueckel Johannes,Huemmer Christian,Shahidi Casra,Buizza Giulia,Hoppe Boj Friedrich,Liebig Thomas,Ricke Jens,Rudolph Jan,Sabel Bastian Oliver

Abstract

Purpose To develop and validate an artificial intelligence algorithm for the positioning assessment of tracheal tubes (TTs) and central venous catheters (CVCs) in supine chest radiographs (SCXRs) by using an algorithm approach allowing for adjustable definitions of intended device positioning. Materials and Methods Positioning quality of CVCs and TTs is evaluated by spatially correlating the respective tip positions with anatomical structures. For CVC analysis, a configurable region of interest is defined to approximate the expected region of well-positioned CVC tips from segmentations of anatomical landmarks. The CVC/TT information is estimated by introducing a new multitask neural network architecture for jointly performing type/existence classification, course segmentation, and tip detection. Validation data consisted of 589 SCXRs that have been radiologically annotated for inserted TTs/CVCs, including an experts' categorical positioning assessment (reading 1). In-image positions of algorithm-detected TT/CVC tips could be corrected using a validation software tool (reading 2) that finally allowed for localization accuracy quantification. Algorithmic detection of images with misplaced devices (reading 1 as reference standard) was quantified by receiver operating characteristics. Results Supine chest radiographs were correctly classified according to inserted TTs/CVCs in 100%/98% of the cases, thereby with high accuracy in also spatially localizing the medical device tips: corrections less than 3 mm in >86% (TTs) and 77% (CVCs) of the cases. Chest radiographs with malpositioned devices were detected with area under the curves of >0.98 (TTs), >0.96 (CVCs with accidental vessel turnover), and >0.93 (also suboptimal CVC insertion length considered). The receiver operating characteristics limitations regarding CVC assessment were mainly caused by limitations of the applied CXR position definitions (region of interest derived from anatomical landmarks), not by algorithmic spatial detection inaccuracies. Conclusions The TT and CVC tips were accurately localized in SCXRs by the presented algorithms, but triaging applications for CVC positioning assessment still suffer from the vague definition of optimal CXR positioning. Our algorithm, however, allows for an adjustment of these criteria, theoretically enabling them to meet user-specific or patient subgroups requirements. Besides CVC tip analysis, future work should also include specific course analysis for accidental vessel turnover detection.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3