Minimizing Surgeon Radiation Exposure During Operative Treatment of Pediatric Supracondylar Humerus Fractures

Author:

Montgomery Blake K.12,Cidambi Emily O.3,Birch Craig M.12,Wang Kemble4,Miller Patricia E.1,Kim Don-Soo5,Shore Benjamin J.12

Affiliation:

1. Department of Orthopaedic Surgery

2. Harvard Medical School, Boston, MA

3. Department of Orthopaedic Surgery, Rady Children’s Hospital, San Diego, CA

4. Melbourne Orthopaedic Surgeon, East Melbourne, Australia

5. Department of Radiology, Boston Children’s Hospital

Abstract

Background: Orthopaedic surgeons are exposed to high levels of radiation, which may lead to higher rates of cancer among orthopaedic surgeons. There are a series of techniques currently practiced to pin supracondylar humerus fractures including pinning the arm on the C-arm itself, using a plexiglass rectangle or a graphite floating arm board; however, the variation in radiation exposure to the surgeon is unknown. We aimed to determine how the position of the C-arm affects radiation exposure to the surgeon during the treatment of a pediatric supracondylar humerus fracture. Material and Methods: A simulated operating room was created to simulate a closed reduction and percutaneous pinning of a supracondylar humerus fracture. A phantom model was used to simulate the patient’s arm. We assessed performing the procedure with the arm on plexiglass, graphite, or on top of the C-arm image receptor. The C-arm was positioned either with the source down and image receptor up (standard position) or with the source up and image receptor down (inverted position). Radiation exposure was recorded from levels corresponding to the surgeon’s head, midline, and groin. The estimated effective dose equivalent was calculated to account for the varying radiation sensitivity of different organs. Results: We found the effective dose equivalent, or the overall body damage from radiation, was 5.4 to 7.8% higher than the surgeon when the C-arm was in the inverted position (source up, image receptor down). We did not find any differences in radiation exposure to the surgeon when the arm was supported on plexiglass versus graphite. Conclusion: The C-arm positioned in the standard fashion exposes the surgeon to less damaging radiation. Therefore, when the surgeon is standing, we recommend using the C-arm in the standard position. Clinical Relevance: Orthopaedic surgeons who stand should use the C-arm in the standard position to pin supracondylar humerus fractures to lower the risk of ionizing radiation exposure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献