Impact on Image Quality and Diagnostic Performance of Dual-Layer Detector Spectral CT for Pulmonary Subsolid Nodules: Comparison With Hybrid and Model-Based Iterative Reconstruction

Author:

Ding Li1ORCID,Li Xiaomei1,Lin Jie1,Deng Shuting1,Chen Mingwang1,Deng Weiwei2,Xu Yikai1,Chen Zhao1,Yan Chenggong1

Affiliation:

1. Department of Medical Imaging Center, Nanfang Hospital of Southern Medical University, Guangzhou, Guangdong, China

2. Clinical and Technical Solution, Philips Healthcare, Shanghai, China.

Abstract

Objective To evaluate the image quality and diagnostic performance of pulmonary subsolid nodules on conventional iterative algorithms, virtual monoenergetic images (VMIs), and electron density mapping (EDM) using a dual-layer detector spectral CT (DLSCT). Methods This retrospective study recruited 270 patients who underwent DLSCT scan for lung nodule screening or follow-up. All CT examinations with subsolid nodules (pure ground-glass nodules [GGNs] or part-solid nodules) were reconstructed with hybrid and model-based iterative reconstruction, VMI at 40, 70, 100, and 130 keV levels, and EDM. The CT number, objective image noise, signal-to-noise ratio, contrast-to-noise ratio, diameter, and volume of subsolid nodules were measured for quantitative analysis. The overall image quality, image noise, visualization of nodules, artifact, and sharpness were subjectively rated by 2 thoracic radiologists on a 5-point scale (1 = unacceptable, 5 = excellent) in consensus. The objective image quality measurements, diameter, and volume were compared among the 7 groups with a repeated 1-way analysis of variance. The subjective scores were compared with Kruskal-Wallis test. Results A total of 198 subsolid nodules, including 179 pure GGNs, and 19 part-solid nodules were identified. Based on the objective analysis, EDM had the highest signal-to-noise ratio (164.71 ± 133.60; P < 0.001) and contrast-to-noise ratio (227.97 ± 161.96; P < 0.001) among all image sets. Furthermore, EDM had a superior mean subjective rating score (4.80 ± 0.42) for visualization of GGNs compared to other reconstructed images (all P < 0.001), although the model-based iterative reconstruction had superior subjective scores of overall image quality. For pure GGNs, the measured diameter and volume did not significantly differ among different reconstructions (both P > 0.05). Conclusions EDM derived from DLSCT enabled improved image quality and lesion conspicuity for the evaluation of lung subsolid nodules compared to conventional iterative reconstruction algorithms and VMIs.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3