Methods and Reproducibility of Liver Fat Measurement Using 3-Dimensional Liver Segmentation From Noncontrast Computed Tomography in EVAPORATE Cohort

Author:

Ding Kimberly R.1,Lakshmanan Suvasini2,Holda Mateusz2,Kinninger April2,Manubolu Venkat S.2,Joshi Tej2,Golub Ilana2,Mao Song S.2,Budoff Matthew J.2,Roy Sion K.2

Affiliation:

1. Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA

2. Department of Cardiology, Harbor-UCLA Medical Center Lundquist Institute, Torrance, CA.

Abstract

Objective Nonalcoholic fatty liver disease not only shares multiple risk factors with cardiovascular disease but also independently predicts its increased risk and related outcomes. Here, we evaluate reproducibility of 3-dimensional (3D) liver volume segmentation method to identify fatty liver on noncontrast cardiac computed tomography (CT) and compare measures with previously validated 2-dimensional (2D) segmentation CT criteria for the measurement of liver fat. Methods The study included 68 participants enrolled in the EVAPORATE trial and underwent serial noncontrast cardiac CT. Liver attenuation < 40 Hounsfield units (HU) was used for diagnosing fatty liver, as done in the MESA study. Two-dimensional and 3D segmentation of the liver were performed by Philips software. Bland-Altman plot analysis was used to assess reproducibility. Results Interreader reproducibility of 3D liver mean HU measurements was 96% in a sample of 111 scans. Reproducibility of 2D and 3D liver mean HU measurements was 93% in a sample of 111 scans. Reproducibility of change in 2D and 3D liver mean HU was 94% in 68 scans. Kappa, a measure of agreement in which the 2D and 3D measures both identified fatty liver, was excellent at 96.4% in 111 scans. Conclusions Fatty liver can be reliably diagnosed and measured serially in a stable and reproducible way by 3D liver segmentation of noncontrast cardiac CT scans. Future studies need to explore the sensitivity and stability of measures for low liver fat content by 3D segmentation, over the current 2D methodology. This measure can serve as an imaging biomarker to understand mechanistic correlations between atherosclerosis, fatty liver, and cardiovascular disease risk.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3