Deep Learning–Based Motion Correction in Projection Domain for Coronary Computed Tomography Angiography: A Clinical Evaluation

Author:

Shuai Tao1,Zhong Sihua2,Zhang Guozhi2,Wang Ziwei1,Zhang Yu1,Li Zhenlin1

Affiliation:

1. Department of Radiology, West China Hospital of Sichuan University, Chengdu

2. United Imaging Healthcare, Shanghai, China

Abstract

Objective This study aimed to evaluate the clinical performance of a deep learning-based motion correction algorithm (MCA) in projection domain for coronary computed tomography angiography (CCTA). Methods A total of 192 patients who underwent CCTA examinations were included and divided into 2 groups based on the average heart rate (HR): group 1, 82 patients with HR of <75 beats per minute; group 2, 110 patients with HR of ≥75 beats per minute. The CCTA images were reconstructed with and without MCA. The subjective image quality was graded in terms of vessel visualization, sharpness, diagnostic confidence, and overall image quality using a 5-point scale, where cases with all scores of ≥3 were deemed interpretable. Objective image quality was measured through signal-to-noise ratio and contrast-to-noise ratio in regions relative to the vessels. The image quality scores for 2 reconstructions and effective dose between 2 groups were compared. Results The mean effective dose was similar between 2 groups. Neither group showed significant difference on objective image quality for 2 reconstructions. Images reconstructed with and without MCA were both found interpretable for group 1, whereas the subjective image quality was significantly improved by the MCA for all 4 metrics in group 2, with the interpretability increased from 80.91% to 99.09%. Compared with group 1, group 2 showed similar interpretability and diagnostic confidence, despite inferior overall image quality. Conclusions In CCTA examinations, the deep learning–based MCA is capable of improving the image quality and diagnostic confidence for patients with increased HR to a similar level as for those with low HR.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3