Feasibility of Epicardial Adipose Tissue Quantification Using Non–electrocardiogram-Gated Chest Computed Tomography Images

Author:

Mikami Tomio1ORCID,Yokomachi Kazushi2,Mizuno Kenji1,Kobayashi Masayuki3

Affiliation:

1. Department of Radiology, Ichiyokai Harada Hospital

2. Department of Diagnostic Radiology, Hiroshima University Hospital

3. Diagnostic Imaging Center, Ichiyokai Harada Hospital, Hiroshima, Japan.

Abstract

Objective Epicardial adipose tissue (EAT) is an important imaging indicator of cardiovascular risk. EAT volume is usually measured using electrocardiogram (ECG) gating. However, there are concerns regarding the influence of motion artifacts when measuring EAT volume on non‐ECG-gated plain chest computed tomography (CT) images. Few studies have evaluated the EAT volume using non-ECG gating. This study aimed to validate the accuracy of EAT quantification using non‐ECG-gated chest CT imaging. Methods We included 100 patients (64 males, 36 females) who underwent simultaneous coronary artery calcification score imaging (ECG gated) and plain chest CT imaging (non‐ECG gated). Images taken using non-ECG gating were reconstructed using the same field of view and slice thickness as those obtained with ECG gating. The EAT capacity of each image was measured and compared. An AZE Virtual Place (Canon) was used for the measurements. The Mann-Whitney U test and intraclass correlation coefficient were used for statistical analyses. P values <0.05 were considered statistically significant. Concordance was evaluated using Bland-Altman analysis. Results The mean EAT volume measured by ECG-gated imaging was 156.5 ± 66.9 mL and 155.4 ± 67.9 mL by non‐ECG-gated imaging, with no significant difference between the two groups (P = 0.86). Furthermore, the EAT volumes measured using ECG-gated and non‐ECG-gated imaging showed a strong correlation (r = 0.95, P < 0.05). Bland-Altman analysis revealed that the mean error of the EAT volume (non‐ECG-gated imaging ‐ ECG-gated imaging) was −1.02 ± 2.95 mL (95% confidence interval, −6.49 to 4.76). Conclusions The EAT volume obtained using non‐ECG-gated imaging was equivalent to that obtained using ECG-gated imaging.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3