Establishing Diagnostic Reference Levels and Radiation Dose for Pediatric Head Age-Based Using Computed Tomography in Khartoum State

Author:

Mohammed Mohammed Hussein Abdullah,Hamza Alnazier O.,Barakat Hana M.,Khider Mohamed O.,Elnour Hanan A.

Abstract

Computed tomography (CT) is a powerful clinical tool for the diagnosis and management of patients, enabling faster and more accurate diagnosis and the avoidance of interventional surgical techniques. A diagnostic reference level (DRL) is a tool used to aid in optimization of protection in the medical exposure of patients for diagnostic and interventional procedures. It is used in medical imaging with ionizing radiation to indicate whether, in routine conditions, the patient dose or administered activity (amount of radioactive material) from a specified procedure is unusually high or low for that procedure. Radiation dosage variance is one of the topics that arise when dealing with CT devices within medical imaging centers. Diagnostic reference levels have not been established in Sudan. The aim of this study is to propose DRLs for CT of the head for 4 pediatric age groups. The 2 levels that this study covers are volume CT dose index based on a 16-cm phantom (CTDIvol [mGy]) and the dose-length products (DLPs [mGy • cm]). These levels were investigated by conducting a survey to 6 healthcare facilities. The survey consists of questions focused on pediatric exposure parameters, CT protocols, and radiation doses for pediatric age groups <1, 1-5, 5-10, and 10-16 years. For the 4 age groups in the 6 facilities that responded, the mean, 25th, 50th, and 75th percentile values of CTDIvol (mGy) for head CT were for infants (<1 year), 21.2, 14.4, 17.6, and 27.0, respectively; for 1-5 years, 36.5, 15.7, 34.5, and 38.1, respectively; for 5- to 10-year group, the CTDIvol was found to be 40, 15.7, 33.5, and 47.6, respectively, and for the last group of 10-16 years, 41.6, 15.7, 37.4, and 58.3, respectively. The corresponding DLP (mGy • cm) for head CT, the mean, 25th, 50th, and 75th percentile values were as follows: for infants (<1 year), 472.9, 326.9, 385.3, and 545.5, respectively; for 1-5 years, 742.9, 509.1, 689.3, and 902.9, respectively; for 5-10 years, 1,130.4, 501.7, 924.2, and 1,667.4, respectively; for 10-16 years, 1,226.4, 595.4, 870.1, and 1,255.3, respectively. The total mean CTDIvol (mGy) was 38.0, and the total mean DLP (mGy · cm) was 1,001.6. These values have been compared with other values from other similar studies; the summary for these comparisons concluded that the majority of CTDIvol 16-cm phantom and DLP 16-cm phantom values for the head were higher than DRLs reported from other studies in other countries. Therefore, for risk reduction, it is necessary to establish DRLs for pediatric CT in Sudan.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference13 articles.

1. Computed tomography: physical principles and recent technical advances;J Med Imaging Radiat Sci,2010

2. CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland;Eur Radiol,2008

3. Sources, effects and risks of ionizing radiation. United Nations Scientific Committee on the Effects of Atomic Radiation. Vol. I, UNSCEAR 2013 report to the general assembly with scientific annexes, volume II, Scientific Annex B, effects of radiation exposure of children

4. Diagnostic reference level of radiation dose and image quality among paediatric CT examinations in a tertiary hospital in Malaysia;Diagnostics (Basel),2020

5. Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan;Pediatr Radiol,2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3