Accuracy of Bladder Scanner in Measuring Bladder Volumes in Postpartum Women

Author:

Zheng Veronica Jierong1,Geynisman-Tan Julia2,Knoll Justin3,Kenton Kimberly2,Brown Oluwateniola2

Affiliation:

1. Feinberg School of Medicine

2. Department of Obstetrics and Gynecology

3. Department of Medical Social Sciences, Northwestern University, Chicago, IL.

Abstract

Importance Ultrasound bladder scanners may provide a less invasive method to measure postpartum urinary volume, but their accuracy must be validated. Objective The objective of this study was to evaluate the accuracy of a bladder scanner in measuring bladder volumes in postpartum women. The secondary objective was to evaluate the effect of obesity on scanner accuracy. Study Design This prospective cohort study included women older than 18 years who gave birth vaginally at term gestation. After delivery, we obtained 3 sequential measurements of the bladder volume using an ultrasound bladder scanner. We then measured true bladder volume by transurethral catheterization. The primary outcome was the absolute difference between the bladder scanner volume and the catheterized volume. A Wilcoxon signed-rank test was used to compare absolute median difference between the bladder scan volume and true catheter volume. Repeated-measures analysis of variance and linear regression were used to evaluate the effect of obesity on the accuracy of the bladder scanner. Results We enrolled 70 patients (61.4% nulliparous, 38.6% multiparous). One delivery was vacuum-assisted, 4 were forceps-assisted, and 65 were spontaneous vaginal. The median age was 34 years, and median body mass index was 30.5. Median difference between bladder scanner and catheter volume was 42.7 mL (P < 0.001), with the scanner underestimating true volume 82.9% of the time. The scanner was less accurate in patients with a body mass index ≥ 30 (P = 0.001). Conclusions The bladder scanner is less accurate than catheterized urine volume. However, the median difference between the bladder scanner and the catheterized volume is 42.7 mL, making it suitable for clinical use. Accuracy deteriorates in obese patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Urology,Obstetrics and Gynecology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Current opinion: postpartum urinary disorders;Current Opinion in Obstetrics & Gynecology;2023-09-29

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3