The Use of a Robotic Arm for Fixation of Pelvic Fractures

Author:

Gilani Syed,Mohamed Mustafa,Hartley Brandi,Zamora Rodolfo,Zou Jiyao,Daccarett Miguel,Carlson Jon B.

Abstract

Objectives: The objective of this study was to evaluate unplanned cortical or neuroforaminal violation of iliosacral and transsacral screw placement using fluoroscopy versus screw placement using a robotic arm. Design: This is a prospective cohort study. Setting: Single surgeon, single North American level 1 trauma center. Patients: Radiographic and clinical data for 21 consecutive adult trauma patients with pelvic ring fractures undergoing surgical treatment were prospectively collected. Treatment consisted of iliosacral and/or transsacral screws with or without anterior fixation. Intervention: Ten patients were treated with the assistance of a robotic arm. Eleven patients were treated with standard fluoroscopic techniques. Main Outcome Measurements: Thirty-two screws were placed and evaluated with postoperative computed tomography or O-arm spins to assess unplanned cortical or neuroforaminal violation. Violations were graded according to the Gertzbein and Robbins system for pedicle screw violation, categorizing screw violation in 2-mm increments. The postoperative images were blindly reviewed by 5 fellowship-trained orthopaedic traumatologists. The treating surgeon was excluded from review. Results: The Mann–Whitney U test on the Gertzbein and Robbins system results demonstrated significantly (P = 0.02) fewer violations with robotic assistance. χ2 analysis of whether there was a cortical violation of any distance demonstrated significantly (P = 0.003) fewer cortical violations with robotic assistance. There were no neurovascular injuries in either group. Conclusion: Robotic assistance demonstrated significantly fewer unplanned cortical or neuroforaminal violations. Further research is needed with additional surgeons and sites to evaluate the accuracy of iliosacral and transsacral screw placement with robotic assistance. Level of Evidence: Therapeutic, level II.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Reference21 articles.

1. Treatment of unstable pelvic ring injuries;Kim;Hip Pelvis,2014

2. Plate versus sacroiliac screw fixation for treating posterior pelvic ring fracture: a Systematic review and meta-analysis;Kim;Injury,2020

3. The antishock iliosacral screw;Gardner;J Orthop Trauma,2010

4. Early results of percutaneous iliosacral screws placed with the patient in the supine position;Routt;J Orthop Trauma,1995

5. Technique for percutaneous iliosacral screw insertion with conventional C-arm radiography;Hilgert;Unfallchirurg,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3