Impact of Prophylactic Cerclage Location on Femoral Fracture Propagation: A Biomechanical Study

Author:

Han Shuyang1,Reddy Kartik I.1,Lanfermeijer Nicholas D.1,Frangie Robert1,Ismaily Sabir K.1,Gold Jonathan E.1ORCID,Lundberg Hannah J.2,Rodriguez-Quintana David1

Affiliation:

1. Department of Orthopedic Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX; and

2. Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL.

Abstract

OBJECTIVES: Prophylactic cerclage cables are often placed intraoperatively about a fracture to prevent propagation. However, biomechanical data supporting optimal cable placement location are lacking. The objective of this study was to evaluate the impact of prophylactic cerclage placement location on the propagation of femoral shaft fractures. METHODS: The diaphysis of 14 fresh-frozen cadaveric femora were included. Volumetric bone mineral density in the femoral shaft was obtained from quantitative computed tomography scans. For each specimen, a 5-mm longitudinal fracture was created proximally to simulate a pre-existing fracture. After reaming of the femoral canal, a 3 degrees tapered wedge was advanced with an MTS machine at 0.2 mm/s until failure. The tests were conducted with a CoCr cable placed at varying distances (5 mm, 10 mm, 15 mm, 20 mm, and cableless) from the distal tip of the initial fracture. A compression loadcell was used to measure the cable tension during the tests. The axial force, displacement, and cable tension were monitored for comparison between groups. RESULTS: In the cableless group, the mean force needed to propagate the fracture was 1017.8 ± 450.3 N. With the addition of a cable at 5 mm below the fracture, the failure force nearly doubled to 1970.4 ± 801.1 N (P < 0.001). This also led to significant increases in stiffness (P = 0.006) and total work (P = 0.001) when compared with the control group. By contrast, in the 15 and 20 mm groups, there were no significant changes in the failure force, stiffness, and total work as compared with the control group (P > 0.05). CONCLUSIONS: Propagation of femoral shaft fracture was effectively resisted when a prophylactic cable was placed within 5 mm from the initial fracture, whereas cables placed more than 10 mm below the initial fracture were not effective in preventing fracture propagation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3