A Strategy for Removing the Bias in the Graphical Analysis Method

Author:

Logan Jean,Fowler Joanna S.,Volkow Nora D.1,Ding Yu Shin,Wang Gene-Jack1,Alexoff David L.

Affiliation:

1. Chemistry and Medical Departments, Brookhaven National Laboratory, Upton, New York, U.S.A.

Abstract

The graphical analysis method, which transforms multiple time measurements of plasma and tissue uptake data into a linear plot, is a useful tool for rapidly obtaining information about the binding of radioligands used in PET studies. The strength of the method is that it does not require a particular model structure. However, a bias is introduced in the case of noisy data resulting in the underestimation of the distribution volume (DV), the slope obtained from the graphical method. To remove the bias, a modification of the method developed by Feng et al. (1993) , the generalized linear least squares (GLLS) method, which provides unbiased estimates for compartment models was used. The one compartment GLLS method has a relatively simple form, which was used to estimate the DV directly and as a smoothing technique for more general classes of model structures. In the latter case, the GLLS method was applied to the data in two parts, that is, one set of parameters was determined for times 0 to T1 and a second set from T1 to the end time. The curve generated from these two sets of parameters then was used as input to the graphical method. This has been tested using simulations of data similar to that of the PET ligand [11C]- d-threo-methylphenidate (MP, DV = 35 mL/mL) and 11C raclopride (RAC, DV = 1.92 mL/mL) and compared with two examples from image data with the same tracers. The noise model was based on counting statistics through the half-life of the isotope and the scanning time. Five hundred data sets at each noise level were analyzed. Results (DV) for the graphical analysis (DVg), the nonlinear least squares (NLS) method (DVnls), the one-tissue compartment GLLS method (DVf), and the two part GLLS followed by graphical analysis (DVfg) were compared. DVFG was found to increase somewhat with increasing noise and in some data sets at high noise levels no estimate could be obtained. However, at intermediate levels it provided a good estimation of the true DV. This method was extended to use a reference tissue in place of the input function to generate the distribution volume ratio (DVR) to the reference region. A linearized form of the simplified reference tissue method of Lammertsma and Hume (1996) was used. The DVR generated directly from the model (DVRfl) was compared with DVRfg (determined from a “smoothed” uptake curve as for DVfg) using the graphical method.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Clinical Neurology,Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3