Abstract

To investigate the reliability of unilateral jugular venous monitoring and to determine the appropriate side, we performed bilateral jugular venous monitoring in 22 head-injured patients. Fiberoptic catheters were placed in both jugular bulbs. Arterial and bilateral jugular venous blood samples were obtained simultaneously for in vitro determination of jugular venous oxygen saturation (SJO2), arterial minus jugular venous lactate content difference (AJDL), and modified lactate-oxygen index (mLOI). Ischemia was assumed if one of the following pathologic values occurred at least unilaterally: SJO2<54%, AJDL <−0.37 mmol/L, mLOI >0.08. The sensitivity of calculated unilateral monitoring in detecting ischemia was evaluated by comparing the incidence detected unilaterally with that disclosed bilaterally. The mean and maximum bilateral SJO2differences varied between 1.4% and 21.0%, and 8.1% and 44.3%, respectively. The bias and limits of agreement (mean differences ± 2 SD) between paired samples were 0.4% ± 12.8%. There was no significant variation in bilateral SJO2differences with time. Decreasing cerebral perfusion pressure (r = −0.559, P < 0.001) and arterial Pco2(r = −0.342, P < 0.001) were associated with increasing bilateral SJO2differences. Regarding AJDL, the maximum bilateral differences varied between 0.04 mmol/L and 1.52 mmol/L. The bias and limits of agreement were −0.01 ± 0.18 mmol/L. At best, 87% of ischemic events were disclosed by monitoring on the side of predominant lesion or, in diffuse injuries, on the side of the larger jugular foramen (computed tomographic [CT] approach). We conclude that in severe head injury, even calculated unilateral jugular venous monitoring has an unpredictable risk for misleading or missing data. Therefore, the reliability of unilateral jugular venous monitoring appears suspicious. For diagnosing ischemia the CT approach is recommended.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Neurology (clinical),Neurology

Cited by 62 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Jugular Bulb Oximetry;Neurocritical Care for Neurosurgeons;2021

2. Intracranial Monitoring in the Neurocritical Care Unit;Neurocritical Care;2019-07-18

3. Cerebral Metabolism and Function;Metabolic Disorders and Critically Ill Patients;2017-08-29

4. Multimodality Monitoring;Neurocritical Care for the Advanced Practice Clinician;2017-08-22

5. Multimodality Monitoring: Illuminating the Comatose Human Brain;Seminars in Neurology;2016-12-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3