Intratest reliability and test–retest reproducibility of the oxygen uptake efficiency slope in healthy participants

Author:

Laethem Christophe Van1,De Sutter Johan2,Peersman Wim1,Calders Patrick1

Affiliation:

1. Department of Rehabilitation Sciences and Physiotherapy, Artevelde University College, Gent

2. Department of Cardiology, Cardiac Rehabilitation Unit, University Hospital, Gent, Belgium

Abstract

Background The oxygen uptake efficiency slope (OUES) is a newer ventilatory exercise parameter, used in the evaluation of healthy participants and patients with cardiovascular disease. However, few data about the reliability and reproducibility of OUES are available. Our study assessed intratest reliability and test-retest reproducibility of OUES in healthy participants. Design and methods Eighteen participants (age 28 ± 6 years, BMI 22.1 ± 1.9 kg/m2, 10 men) performed two identical maximal exercise tests on a bicycle ergometer. To assess test-retest reproducibility, we performed Bland-Altman analysis and calculated the coefficient of repeatability of the main ventilatory variables. Results OUES remained stable during the second part of the exercise test. Mean values varied 2.4 ± 4.0% between OUES calculated at 70% (OUES70) and at 100% of exercise duration. Mean variation decreased to 1.4 ± 2.3% when OUES was calculated at 90% of exercise duration (OUES90). The Bland-Altman 95% limits of agreement for OUES90 were +3 and –6%, those for OUES70 were +11 and –8%. The coefficient of repeatability for OUES was 597 ml/min or 18.7% of the average value of repeated OUES measurements. These results were similar to those of peak oxygen uptake and minute ventilation/carbon dioxide output. However, the test-retest reproducibility for submaximal-derived values of OUES was lower, as we noted higher coefficients of repeatability for OUES90 and OUES70, increasing up to 27% of the average of repeated values. Conclusion OUES shows excellent intratest reliability and has a test-retest reproducibility that is similar to that of peak oxygen uptake and minute ventilation/carbon dioxide output slope. However, its reproducibility becomes higher when it is calculated from increasing levels of achieved exercise intensity.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Epidemiology

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3