Feasibility of Saphenous Nerve Somatosensory-Evoked Potential Intraoperative Monitoring during Lumbar Spine Surgery

Author:

Rucker Sydney1,Singh Nishtha2,Mai Eric3,Asada Tomoyuki2,Shahi Pratyush2,Mercado Kristin1,Leung Dora13,Iyer Sravisht23,Emerson Ronald13,Qureshi Sheeraz A.23

Affiliation:

1. Department of Neurology, Hospital for Special Surgery, New York, NY, USA

2. Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA

3. Weill Cornell Medical College, New York, NY, USA

Abstract

Study Design. Retrospective review. Objective. Assess the feasibility of saphenous nerve somatosensory evoked potentials (SN-SSEP) monitoring in lumbar spine surgeries. Background Context. SN-SSEPs have been proposed for detecting lumbar plexus and femoral nerve injury during lateral lumbar surgery where tibial nerve (TN)SSEPs alone are insufficient. SN-SSEPs may also be useful in other types of lumbar surgery, as stimulation of SN below the knee derives solely from the L4 root and provides a means of L4 monitoring, whereas TN-SSEPs often do not detect single nerve root injury. The feasibility of routine SN-SSEP monitoring has not been established. Methods. A total of 563 consecutive cases using both TN and SN-SSEP monitoring were included. Anesthesia was at the discretion of the anesthesiologist, using an inhalant in 97.7% of procedures. SN stimulation was performed using 13 mm needle electrodes placed below the knee using 200-400 μsec pulses at 15-100 mA. Adjustments to stimulation parameters were made by the neurophysiology technician while obtaining baselines. Data were graded retrospectively for monitorability and cortical response amplitudes were measured by two independent reviewers. Results. 98% of TN-SSEPs and 92.5% of SN-SSEPs were monitorable at baseline, with a mean response amplitude of 1.35 μV for TN-SSEPs and 0.71 μV for SN-SSEPs. A significant difference between the stimulation parameters used to obtain reproducible TN and SN-SSEPs at baseline was observed, with SN-SSEPs requiring greater stimulation intensities. Body mass index (BMI) is not associated with baseline monitorability. Out of 20 signal changes observed, 11 involved SN while TN-SSEPs were unaffected. Conclusion. With adjustments to stimulation parameters, SN-SSEP monitoring is feasible within a large clinical cohort without modifications to the anesthetic plan. Incorporating SN into standard intraoperative neurophysiological monitoring (IONM) protocols for lumbar spine procedures may expand the role of SSEP monitoring to include detecting injury to the lumbar plexus. Level of Evidence. 3

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3