Detection and Characterization of Endplate Structural Defects on CT

Author:

Lawan Aliyu1,Leung Andrew2,Leung Stephanie2,Faul James3,Umoh Joseph U.4,Holdsworth David W.45,Bryant Dianne M.1,Battié Michele C.1

Affiliation:

1. Faculty of Health Sciences, School of Physical Therapy, and Western’s Bone and Joint Institute, Western University, London, ON, Canada

2. Department of Medical Imaging, Victoria Hospital, London Health Sciences Centre, London, ON, Canada

3. Department of Anatomy and Cell Biology, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada

4. Preclinical Imaging Research Centre, Robarts Research Institute, Western University, London, ON, Canada

5. Departments of Medical Biophysics and Surgery, Western University, London, ON, Canada

Abstract

Study Design. Diagnostic test study. Objective. To determine the reliability and validity or diagnostic accuracy of two previously described endplate structural defect (EPSD) assessment methods. Summary of Background Data. Studies of EPSD may further the understanding of pathoanatomic mechanisms underlying back pain. However, clinical imaging methods used to document EPSD have not been validated, leaving uncertainty about what the observations represent. Materials and Methods. Using an evaluation manual, 418 endplates on CT sagittal slices obtained from 19 embalmed cadavers (9 men and 10 women, aged 62–91 yr) were independently assessed by two experienced radiologists and a novice for EPSD using the two methods. The corresponding micro-CT (µCT) from the harvested T7-S1 spines were assessed by another independent rater with excellent intra-rater reliability (k=0.96). Results. Inter-rater reliability was good for the presence (k=0.60–0.69) and fair for specific phenotypes (k=0.43-0.58) of EPSD. Erosion, for which the Brayda-Bruno classification lacked a category, was mainly (82.8%) classified as wavy/irregular, while many notched defects (n=15, 46.9%) and Schmorl’s nodes (n=45, 79%) were recorded as focal defects using Feng’s classification. When compared to µCT, endplate fractures (n=53) and corner defects (n=28) were routinely missed on CT. Endplates classified as wavy/irregular on CT corresponded to erosion (n=29, 21.2%), jagged defects (n=21, 15.3%), calcification (n=19, 13.9%), and other phenotypes on µCT. Some focal defects on CT represented endplate fractures (n=21, 27.6%) on µCT. Overall, with respect to the presence of an EPSD, there was a sensitivity of 70.9% and a specificity of 79.1% using Feng's method, and 79.5% and 57.5% using Brayda-Bruno's method. Poor to fair inter-rater reliability (k=0.26–0.47) was observed for defect dimensions. Conclusion. There was good inter-rater reliability and evidence of criterion validity supporting assessments of EPSD presence using both methods. However, neither method contained all needed EPSD phenotypes for optimal sensitivity, and specific phenotypes were often misclassified.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3