Predictors of Subsidence and its Clinical Impact After Expandable Cage Insertion in Minimally Invasive Transforaminal Interbody Fusion

Author:

Subramanian Tejas12,Merrill Robert K.1,Shahi Pratyush1,Pathania Shane12,Araghi Kasra1,Maayan Omri12,Zhao Eric12,Shinn Daniel12,Kim Yeo Eun12,Kamil Robert1,Song Junho1,Dalal Sidhant S.1,Vaishnav Avani S.1,Othman Yahya1,Steinhaus Michael E.1,Sheha Evan D.1,Dowdell James E.1,Iyer Sravisht12,Qureshi Sheeraz A.12ORCID

Affiliation:

1. Hospital for Special Surgery, New York, NY

2. Weill Cornell Medical College, New York, NY

Abstract

Study Design. Retrospective review of prospectively collected multisurgeon data. Objective. Examine the rate, clinical impact, and predictors of subsidence after expandable minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) cage. Summary of Background Data. Expandable cage technology has been adopted in MI-TLIF to reduce the risks and optimize outcomes. Although subsidence is of particular concern when using expandable technology as the force required to expand the cage can weaken the endplates, its rates, predictors, and outcomes lack evidence. Materials and Methods. Patients who underwent 1 or 2-level MI-TLIF using expandable cages for degenerative lumbar conditions and had a follow-up of >1 year were included. Preoperative and immediate, early, and late postoperative radiographs were reviewed. Subsidence was determined if the average anterior/posterior disc height decreased by >25% compared with the immediate postoperative value. Patient-reported outcomes were collected and analyzed for differences at the early (<6 mo) and late (>6 mo) time points. Fusion was assessed by 1-year postoperative computed tomography. Results. One hundred forty-eight patients were included (mean age, 61 yr, 86% 1-level, 14% 2-level). Twenty-two (14.9%) demonstrated subsidence. Although statistically not significant, patients with subsidence were older, had lower bone mineral density, and had higher body mass index and comorbidity burden. Operative time was significantly higher (P = 0.02) and implant width was lower (P < 0.01) for subsided patients. Visual analog scale-leg was significantly lower for subsided patients compared with nonsubsided patients at a >6 months time point. Long-term (>6 mo) patient-acceptable symptom state achievement rate was lower for subsided patients (53% vs. 77%), although statistically not significant (P = 0.065). No differences existed in complication, reoperation, or fusion rates. Conclusions. Of the patients, 14.9% experienced subsidence predicted by narrower implants. Although subsidence did not have a significant impact on most patient-reported outcome measures and complication, reoperation, or fusion rates, patients had lower visual analog scale-leg and patient-acceptable symptom state achievement rates at the >6-month time point. Level of Evidence. Level 4.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3