Hooks Versus Pedicle Screws at the Upper Instrumented Level

Author:

Colantonio Donald F.12,Le Anthony H.3,Pisano Alfred J.12,Chung Joon M.4,Wagner Scott C.12,Fredericks Donald R.12,Roach William B.12,Schlaff Cody12,Dill Andrew5,Mauntel Timothy C.26,Hendershot Brad D.37,Helgeson Melvin D.12

Affiliation:

1. Department of Orthopaedics, Walter Reed National Military Medical Center, Bethesda, MD

2. Department of Surgery, Uniformed Services University of the Health Sciences, Bethesda, MD

3. DoD-VA Extremity Trauma and Amputation Center of Excellence, Walter Reed National Military Medical Center, Bethesda, MD

4. School of Medicine, Georgetown University, Washington, DC

5. School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD

6. DoD-VA Extremity Trauma and Amputation Center of Excellence, Womack Army Medical Center, Fort Bragg, NC

7. Department of Rehabilitation Medicine, Uniformed Services University of the Health Science, Bethesda, MD

Abstract

Study Design. Controlled laboratory study. Objective. The aim was to compare motions at the upper instrumented vertebra (UIV) and supra-adjacent level (UIV+1) between two fixation techniques in thoracic posterior spinal fusion constructs. We hypothesized there would be greater motion at UIV+1 after cyclic loading across all constructs and bilateral pedicle screws (BPSs) with posterior ligamentous compromise would demonstrate the greatest UIV+1 range of motion. Summary of Background Data. Proximal junctional kyphosis is a well-recognized complication following long thoracolumbar posterior spinal fusion, however, its mechanism is poorly understood. Materials and Methods. Twenty-seven thoracic functional spine units were randomly divided into three UIV fixation groups (n=9): (1) BPS, (2) bilateral transverse process hooks (TPHs), and (3) BPS with compromise of the posterior elements between UIV and UIV+1 (BPS-C). Specimens were tested on a servohydraulic materials testing system in native state, following instrumentation, and after cyclic loading. functional spine units were loaded in flexion-extension (FE), lateral bending, and axial rotation. Results. After cyclic testing, the TPH group had a mean 29.4% increase in FE range of motion at UIV+1 versus 76.6% in the BPS group (P<0.05). The BPS-C group showed an increased FE of 49.9% and 62.19% with sectioning of the facet joints and interspinous ligament respectively prior to cyclic testing. Conclusion. BPSs at the UIV led to greater motion at UIV+1 compared to bilateral TPH after cyclic loading. This is likely due to the increased rigidity of BPS compared to TPH leading to a “softer” transition between the TPH construct and native anatomy at the supra-adjacent level. Facet capsule compromise led to a 49.9% increase in UIV+1 motion, underscoring the importance of preserving the posterior ligamentous complex. Clinical studies that account for fusion rates are warranted to determine if constructs with a “soft transition” result in less proximal junctional kyphosis in vivo.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3