Abstract

Study Design. Systematic Review Objective. We sought to determine which method of the pedicle screw (PS) placement is most accurate and understand how the development of subsequent generations of robotic systems has changed placement accuracy over time. Summary of Background Data. Previous studies have demonstrated the success of robotic PS placement, but how this accuracy compares to other methods is unclear. Methods. A systematic review following PRISMA Guidelines was performed on articles published between January 2000 and August 2021, comparing PS insertion methods with at least 10 screws per study arm. Single and multiple-arm trials were included. Data were extracted for patient outcomes, including optimal PS placement, misplacement, and accuracy. The logit-event rate of misplacement was calculated for each study. P values were adjusted for multiple comparisons using the Tukey post hoc correction. Results. Our search revealed 127 studies, and 156 comparative arms, with 77,360 pedicle screws placed using five different modalities. Meta-regression of pooled accuracy revealed no significant changes in PS accuracy over time for freehand, 2D fluoroscopic navigation, 3D fluoroscopic navigation, and computed tomography navigation. Robotic navigation had a significant increase in accuracy over time (P=0.036). Pooled misplacement rates were also compared across all modalities. Robotics was found to have the lowest rates of misplacement for PS compared to freehand (P=0.0015) and 2D fluoroscopic navigation (P=0.026). Conclusion. Our analysis is the largest study to date on pedicle screw placement. Pedicle screw placement through robotics was found to be superior due to its low misplacement rates compared with other modalities. Intraoperative 3D fluoroscopic navigation was found to have comparable misplacement rates. In addition, pedicle screw placement accuracy with robotics has continued to improve over time. This speaks to both the stability of the technology and the potential for continued improvement with new and more accurate robotic systems.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3