Individualised positive end-expiratory pressure titrated intra-operatively by electrical impedance tomography optimises pulmonary mechanics and reduces postoperative atelectasis

Author:

Ma Xiaojing,Fu Yunke,Piao Xiangmei,De Santis Santiago Roberta Ribeiro,Ma Libin,Guo Ying,Fu Qiang,Mi Weidong,Berra Lorenzo,Zhang Changsheng

Abstract

BACKGROUND A protective intra-operative lung ventilation strategy has been widely recommended for laparoscopic surgery. However, there is no consensus regarding the optimal level of positive end-expiratory pressure (PEEP) and its effects during pneumoperitoneum. Electrical impedance tomography (EIT) has recently been introduced as a bedside tool to monitor lung ventilation in real-time. OBJECTIVE We hypothesised that individually titrated EIT-PEEP adjusted to the surgical intervention would improve respiratory mechanics during and after surgery. DESIGN Randomised controlled trial. SETTING First Medical Centre of Chinese PLA General Hospital, Beijing. PATIENTS Seventy-five patients undergoing robotic-assisted laparoscopic hepatobiliary and pancreatic surgery under general anaesthesia. INTERVENTIONS Patients were randomly assigned 2 : 1 to individualised EIT-titrated PEEP (PEEPEIT; n = 50) or traditional PEEP 5 cmH2O (PEEP5 cmH2O; n = 25). The PEEPEIT group received individually titrated EIT-PEEP during pneumoperitoneum. The PEEP5 cmH2O group received PEEP of 5 cmH2O during pneumoperitoneum. MAIN OUTCOME MEASURES The primary outcome was respiratory system compliance during laparoscopic surgery. Secondary outcomes were individualised PEEP levels, oxygenation, respiratory and haemodynamic status, and occurrence of postoperative pulmonary complications (PPCs) within 7 days. RESULTS Compared with PEEP5 cmH2O, patients who received PEEPEIT had higher respiratory system compliance (mean values during surgery of 44.3 ± 11.3 vs. 31.9 ± 6.6, ml cmH2O−1; P < 0.001), lower driving pressure (11.5 ± 2.1 vs. 14.0 ± 2.4 cmH2O; P < 0.001), better oxygenation (mean P aO2/FiO2 427.5 ± 28.6 vs. 366.8 ± 36.4; P = 0.003), and less postoperative atelectasis (19.4 ± 1.6 vs. 46.3 ± 14.8 g of lung tissue mass; P = 0.003). Haemodynamic values did not differ significantly between the groups. No adverse effects were observed during surgery. CONCLUSION Individualised PEEP by EIT may improve intra-operative pulmonary mechanics and oxygenation without impairing haemodynamic stability, and decrease postoperative atelectasis. TRIAL REGISTRATION Chinese Clinical Trial Registry (www.chictr.org.cn) identifier: ChiCTR2100045166.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference29 articles.

1. Anatomical changes due to pneumoperitoneum analyzed by MRI: an experimental study in pigs;Sanchez-Margallo;Surg Radiol Anat,2011

2. Effect of carbon dioxide pneumoperitoneum on development of atelectasis during anesthesia, examined by spiral computed tomography;Andersson;Anesthesiology,2005

3. Incentive spirometry for prevention of postoperative pulmonary complications in upper abdominal surgery;Guimaraes;Cochrane Database Syst Rev,2009

4. Protective lung ventilation in operating room: a systematic review;Futier;Minerva Anestesiol,2014

5. Effects of intraoperative protective lung ventilation on postoperative pulmonary complications in patients with laparoscopic surgery: prospective, randomized and controlled trial;Park;Surg Endosc,2016

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3