Evaluation of the non-invasive Temple Touch Pro temperature monitoring system compared with oesophageal temperature in paediatric anaesthesia (PETER PAN)

Author:

Nemeth Marcus,Klose Katharina,Asendorf Thomas,Pancaro Carlo,Mielke Benjamin,Fazliu Albulena,Saager Leif,Bräuer Anselm,Miller Clemens

Abstract

BACKGROUND Monitoring peri-operative body temperature in children is currently mainly achieved through invasive devices. The Temple Touch Pro Temperature Monitoring System estimates core temperature noninvasively based on heat flux thermometry. OBJECTIVE To investigate the agreement of this noninvasive sensor against standard oesophageal core temperature. DESIGN A prospective observational study. SETTING University hospital recruiting between April and July 2021. PATIENTS One hundred children (32 girls) aged 6 years or younger scheduled for noncardiac surgery, resulting in 6766 data pairs. Exclusion criteria were contraindication for the insertion of an oesophageal temperature probe, and procedures in which one of the measurement methods would interfere with the surgical field. MAIN OUTCOME MEASURES Primary outcome was the agreement analysis by a Bland–Altman comparison with multiple measurements. Posthoc, we performed another agreement analysis after exclusion of a statistically determined equilibration time. Secondary outcomes were the temperature differences over time and subgroup analysis of hypothermic, normothermic and hyperthermic temperature ranges, age, sex and sensor's side by type III analysis of variance. Further, we correlated the sonographically determined depth of the artery with trueness. RESULTS The mean difference was -0.07°C (95% CI –0.15 to +0.05) with limits of agreement of -1.00 and +0.85°C. After adjusting for an equilibration time of 13 min, the mean difference improved to –0.04°C (95% CI –0.08 to +0.01) with limits of agreement of –0.68 and +0.60°C. Concordance correlation coefficient was 0.83 (95% CI 0.82 to 0.84). Differences between the skin sensor and oesophageal reference increased over time by -0.05°C per hour. Subgroup analysis showed no clinically relevant differences. Depth of artery negatively correlated with trueness by 0.03°C per millimetre. CONCLUSIONS Although the Temple Touch Pro sensor showed acceptable accuracy after allowing for an equilibration time, it still needs further investigation for routine use in children. This particularly affects accuracy in hypothermic ranges, imprecise positioning and applicability in children with immature or vulnerable skin. TRIAL REGISTRATION German Clinical Trials Register, identifier: DRKS00024703

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3