Affiliation:
1. Nuclear Medicine
2. Surgical Gastroenterology, Jawaharlal Institute of Post Graduate Medical Education and Research, Puducherry, India.
Abstract
Introduction and Aim
Preliminary studies showed good expression of fibroblast activating protein inhibitor (FAPI) in hepatocellular carcinoma (HCC) and cholangiocarcinoma (CC). Our aims were to study the diagnostic performance of 68Ga-FAPI PET/CT in diagnosing the primary hepatobiliary malignancies and to compare its performance with 18F-FDG PET/CT.
Patients and Methods
Patients suspected to have HCC and CC were recruited prospectively. FDG and FAPI PET/CT studies were completed within 1 week. Final diagnosis of malignancy was achieved by tissue diagnosis (either histopathological examination or fine-needle aspiration cytology) and radiological correlation from conventional modalities. Results were compared with final diagnosis and expressed as sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy.
Results
Forty-one patients were included. Thirty-one were positive for malignancy and 10 were negative. Fifteen were metastatic. Of 31, 18 were CC and 6 were HCC. For overall diagnosis of the primary disease, FAPI PET/CT performed exceptionally compared with FDG PET/CT with sensitivity, specificity, and accuracy of 96.77%, 90%, and 95.12%, respectively, versus 51.61%, 100%, and 63.41% for FDG PET/CT. FAPI PET/CT clearly outperformed FDG PET/CT for the evaluation of CC with sensitivity, specificity, and accuracy of 94.4%, 100%, and 95.24%, respectively, whereas for FDG PET/CT sensitivity, specificity, and accuracy were 50%, 100%, and 57.14%, respectively. Diagnostic accuracy of FAPI PET/CT was 61.54% for metastatic HCC compared with 84.62% for FDG PET/CT.
Conclusions
Our study highlights the potential role of FAPI-PET/CT in evaluating CC. It also ascertains its usefulness in the cases of mucinous adenocarcinoma. Although it showed a higher lesion detection rate than FDG in primary HCC, its diagnostic performance in the metastatic setting is questionable.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Radiology, Nuclear Medicine and imaging,General Medicine
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献