Abstract

Laboratory compliance implies to correlate instruments for coagulation parameter with a wide range of measure using patient samples or commercialized sets of frozen plasmas. The aim of this study was to evaluate the intra, inter-reproducibility and long-term stability of ExpertCor Routine (ECR) plasma sets (Stago) on different parameters. The study was realized in two laboratories on four different instruments. Inter-site and intra-site correlation of ECR sets for PT, aPTT, Fibrinogen, INR, factor V (FV) UFH and LMWH anti-Xa and intra-reproducibility of DDimer (DDI), factor VIII (FVIII:C) and antithrombin (AT) assays were tested. To evaluate ECR long-term stability, samples were tested until 180 after delivery in one laboratory. Intra-site evaluation correlation coefficients is around 1. All predefined criteria to fulfil good comparability between inter-site instruments are met with Passing slopes between 0.9 and 1.1 and intercepts ranging from −0.62 to 2.83%. Long-term stability evaluation does not show any deviation over 180 days for aPTT, fibrinogen, DDI, UFH, LMWH but a drift for FV with STA-NeoPTimal reagent. On contrary, AT and FVIII:C are not stable. PT in second has an excellent stability unlike PT in percentage. Our study validates the use of ECR sets for correlation between instruments and inter-sites agreement, as for parameters claimed on the products than for factor V and FVIII:C. The evaluation of stability confirming the possible extension of use for 180 days after delivery except for FVIII:C and AT. These plasmas sets are an excellent alternative to local plasma patient use to perform instrument comparison.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Hematology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3