High Interobserver Agreement on PSMA PET/CT Even in the Absence of Clinical Data

Author:

Bundschuh Ralph A.1,Lütje Susanne2,Bundschuh Lena1,Lapa Constantin1,Higuchi Takahiro,Hartrampf Philipp E.3,Gorin Michael A.4,Kosmala Aleksander3,Buck Andreas K.3,Pomper Martin G.,Rowe Steven P.,Essler Markus5,Sheikh Gabriel T.6,Werner Rudolf A.

Affiliation:

1. Medical Faculty, Department of Nuclear Medicine, University Hospital Augsburg, Augsburg, Germany

2. Department of Nuclear Medicine, University Hospital Aachen, Aachen, Germany

3. Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany

4. Milton and Carroll Petrie Department of Urology, Icahn School of Medicine at Mount Sinai, New York, NY

5. Department of Nuclear Medicine, University Hospital Bonn, Bonn, Germany

6. Department of Nuclear Medicine, Ludwig Maximilian University of Munich, Munich, Germany

Abstract

Background Recommended by current guidelines, prostate-specific membrane antigen (PSMA)–directed PET/CT is increasingly used in men with prostate cancer (PC). We aimed to provide concordance rates using the PSMA reporting and data system (RADS) for scan interpretation and also determine whether such agreement rates are affected by available patient characteristics at time of scan. Patients and Methods Sixty men with PC, who all underwent 68Ga-PSMA-11 PET/CT, were included. Three independent, experienced readers indicated general scan parameters (including overall scan result, organ or lymph node [LN] involvement, and appropriateness of radioligand therapy). Applying PSMA-RADS 1.0, observers also had to conduct RADS scoring on a target lesion (TL) and overall scan level. During the first read, observers were masked to all relevant clinical information, whereas on a second read, relevant patient characteristics were displayed, thereby allowing for determination of impact of available clinical information for scan interpretation. We used intraclass correlation coefficients (ICCs; with 95% confidence intervals [CIs]), which were then rated according to Cicchetti (0.4–0.59 fair, 0.6–0.74 good, and 0.75–1 excellent agreement). Results For general parameters, agreement rates were excellent, including an overall scan result (ICC, 0.85; 95% CI, 0.76–0.90), LN metastases (ICC, 0.89; 95% CI, 0.83–0.93), organ involvement (ICC, 0.82; 95% CI, 0.72–0.89), and indication for radioligand therapy (ICC, 0.94; 95% CI, 0.90–0.96). Overall RADS scoring was also excellent with an ICC of 0.91 (95% CI, 0.96–09.4). On a TL-based level, 251 different lesions were selected by the 3 observers (with 73 chosen by all 3 readers). RADS-based concordance rates were fair to excellent: all lesions, ICC of 0.78 (95% CI, 0.67–0.85); LN, ICC of 0.81 (95% CI, 0.63–0.92); skeleton, ICC of 0.55 (95% CI, 0–0.84); and prostate, ICC of 0.48 (95% CI, 0.17–0.78). When performing a second read displaying patient’s characteristics, there were only minor modifications to the previously applied RADS scoring on a TL-based level (overall, n = 8): each reader 1 and 2 in 3/60 (5%) instances, and reader 3 in 2/60 (3.3%) instances. The main reason for recategorization (mainly upstaging) was provided information on PSA levels (4/8, 50%). Conclusions Applying PSMA-RADS, concordance rates were fair to excellent, whereas relevant modifications were rarely observed after providing clinical data. As such, even in the absence of patient information, standardized frameworks still provide guidance for reading PSMA PETs. Those findings may have implications for a high throughput in a busy PET practice, where patient details cannot always be retrieved at time of scan interpretation or in the context of clinical trials or central reviews in which readers may be blinded to clinical data.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3