Interobserver Agreement Rates on C-X-C Motif Chemokine Receptor 4–Directed Molecular Imaging and Therapy

Author:

Hartrampf Philipp E.1,Kosmala Aleksander1,Serfling Sebastian E.1,Bundschuh Lena2,Higuchi Takahiro3,Lapa Constantin2,Rowe Steven P.4,Matsusaka Yohji1,Weich Alexander,Buck Andreas K.1,Bundschuh Ralph A.2,Werner Rudolf A.

Affiliation:

1. Department of Nuclear Medicine, University Hospital Würzburg, Würzburg

2. Nuclear Medicine, Medical Faculty, University Hospital Augsburg, Augsburg, Germany

3. Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan

4. Johns Hopkins School of Medicine, The Russell H Morgan Department of Radiology and Radiological Sciences, Baltimore, MD

Abstract

Background We aimed to evaluate the interobserver agreement rates in patients scanned with C-X-C motif chemokine receptor 4 (CXCR4)–directed PET/CT, including the rate of patients eligible for CXCR4-targeted radioligand therapy (RLT) based on scan results. Methods Four independent observers reviewed 50 CXCR4-targeted [68Ga]pentixafor PET/CT of patients with various solid cancers. On a visual level, the following items were assessed by each reader: overall scan impression, number of organ and lymph node (LN) metastases and number of affected organs and LN regions. For a quantitative investigation, readers had to choose a maximum of 3 target lesions, defined as largest in size and/or most intense uptake per organ compartment. Reference tissues were also quantified, including unaffected hepatic parenchyma and blood pool. Last, all observers had to decide whether patients were eligible for CXCR4-targeted RLT. Concordance rates were tested using intraclass correlation coefficients (ICCs). For interpretation, we applied the definition of Cicchetti (with 0.4–0.59 indicating fair; 0.6–0.74, good; 0.75–1, excellent agreement). Results On a visual level, fair agreement was achieved for an overall scan impression (ICC, 0.58; 95% confidence interval, 0.45–0.71). Organ and LN involvement (ICC, ≥0.4) demonstrated fair, whereas CXCR4 density and number of LN and organ metastases showed good agreement rates (ICC, ≥0.65). Number of affected organs and affected LN areas, however, showed excellent concordance (ICC, ≥0.76). Quantification in LN and organ lesions also provided excellent agreement rates (ICC, ≥0.92), whereas quantified uptake in reference organs provided fair concordance (ICC, ≥0.54). Again, excellent agreement rates were observed when deciding on patients eligible for CXCR4-RLT (ICC, 0.91; 95% confidence interval, 0.85–0.95). Conclusions In patients scanned with CXCR4-targeted PET/CT, we observed fair to excellent agreement rates for both molecular imaging and therapy parameters, thereby favoring a more widespread adoption of [68Ga]pentixafor in the clinic.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3