Evaluating Moisture Migration in Schirmer Test Strips: Exploring Brand-Specific Variations and Introducing Calibration and Conversion Methods

Author:

Magone M. Teresa1ORCID,Schuck Peter2

Affiliation:

1. Consult Services Section, National Eye Institute, National Institutes of Health, Bethesda, MD; and

2. Laboratory of Dynamics of Macromolecular Assembly, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD.

Abstract

Purpose: Schirmer test results are widely used for ocular surface disease assessment, but Schirmer strips are not standardized. We compare the characteristics and tear volume with millimeter moisture migration in different brands of Schirmer strips and introduce methods for volume-based, brand-independent calibration. Methods: Physical parameters of Haag-Streit, EagleVision, TearFlo, Contacare, and MIPL/A6 Schirmer strip brands were compared. Schirmer strip millimeter moisture migration distances were assessed 5 minutes after application of incremental microliter volumes of human tears. Linear regression analysis of data points from each Schirmer strip brand was performed, and the root-mean-square deviation of data points to the best-fit linear regression was calculated. Calibration correction was performed by converting migration distance to the corresponding tear volume. A reference table and calibration method formulas were created. Results: Schirmer strips differed in design, shape, and manufacturing precision. Strip width, weight, and length were different between the 5 brands (P < 0.05). A wide range of Schirmer strip moisture migration values for identical tear volumes was observed among brands. Statistical measurement resulted in a root-mean-square deviation of 2.9 mm for all data points from all brands. Millimeter to volume and weight to volume-based calibration correction methods resulted in a 2.2- and 3.1-fold measurement error reduction, respectively. Conclusions: Our findings highlight the lack of standardization among different brands of Schirmer strips, raising concerns about potential sources of unintentional measurement errors. We propose volume-based Schirmer strip calibration methods and conversion of millimeter to microliter results to achieve brand-independent results and improve Schirmer test accuracy.

Funder

Office of Research on Women's Health

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3