Size and Shape Matter: Cell Viability of Preloaded Descemet Stripping Automated Endothelial Keratoplasty Grafts in Three Different Carriers

Author:

Straiko Megan M. W.1ORCID,Sawant Onkar B.2,Hubbs Rebecca1,Dye Philip K.1,Tsering Dolkar1,Hicks Nicholas3,Odell Kelly1,Ellison Mark S.1,Titus Michael S.3,Straiko Michael D.4,Tran Khoa D.1

Affiliation:

1. VisionGift, Portland, OR;

2. Center for Vision and Eye Banking Research, Eversight, Cleveland, OH; and

3. Department of Clinical Operations, Eversight, Ann Arbor, MI;

4. Devers Eye Institute, Portland, OR.

Abstract

Purpose: The aim of this study was to examine endothelial cell loss (ECL) associated with preloaded Descemet stripping automated endothelial keratoplasty (DSAEK) grafts loaded into 3 carriers of different size and shape. Methods: Thirty-six donor corneas were prepared for DSAEK and loaded into an EndoGlide Ultrathin (control) (2.0 mm × 3.5 mm lumen, 4.5 mm/4.9 mm incision for scleral tunnel/clear corneal insertion), Descemet membrane endothelial keratoplasty EndoGlide (experimental) (1.1 mm × 1.7 mm lumen, 2.65 mm incision), or round glass Jones tube (experimental) (1.8 mm lumen, 3.0 mm incision). Control grafts were stored for 6 days in Optisol-GS and experimental grafts stored for 24 hours in Life4C before analysis using Calcein AM staining. Grafts were imaged and ECL was analyzed by FIJI segmentation. The statistical significance of ECL was determined using 1-way ANOVA and Tukey post hoc analysis. Results: There were no significant differences in donor characteristics for grafts in each cohort. ECL for grafts loaded into the EndoGlide Ultrathin was 10.3% ± 2.3% (graft thickness: 60–189 μm, n = 9). ECL for grafts loaded into the Descemet membrane endothelial keratoplasty EndoGlide was 22.2% ± 7.1% (graft thickness: 38–63 μm, n = 9). ECL for thin grafts (34–60 μm, n = 9) loaded into the Jones tube was 24.0% ± 5.0%. ECL for thick grafts (92–119 μm, n = 9) loaded into the Jones tube was 34.2% ± 6.1% ECL (P < 0.001). Combined regression analysis revealed that graft thickness is directly correlated to ECL (P < 0.01). Conclusions: The size and shape of the carrier can influence the cell viability of preloaded DSAEK grafts. Compared with a larger carrier, smaller lumen carriers are associated with greater ECL. In smaller lumen carriers, ECL increases with increasing DSAEK graft thickness.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3