Early Outcomes of an Artificial Endothelial Replacement Membrane Implantation After Failed Repeat Endothelial Keratoplasty

Author:

Fontana Luigi12ORCID,di Geronimo Natalie12,Cennamo Michela3,Mencucci Rita3,Versura Piera12,Moramarco Antonio12

Affiliation:

1. Ophthalmology Unit, Dipartimento di Scienze Mediche e Chirurgiche, Alma Mater Studiorum University of Bologna, Bologna, Italy;

2. IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy; and

3. Ophthalmology Unit, Azienda Ospedaliero-Universitaria Careggi, UNIFARBA Department, University of Florence, Florence, Italy.

Abstract

Purpose: The purpose of this study was to report the outcomes of a novel artificial endothelial replacement membrane implant for treating corneal edema after failed repeat endothelial keratoplasty (EK). Design: This was a retrospective interventional case series. Methods: Patients with chronic corneal edema underwent removal of the EK graft and implantation of an artificial endothelial replacement membrane (EndoArt, EyeYon Medical, Israel) several months after 2 or more Descemet stripping endothelial keratoplasty procedures. The implant was secured to the posterior corneal surface using an air–gas bubble. Outcome measures included corrected distance visual acuity (logMAR), central corneal thickness, device-related complications, and ocular discomfort. Results: Five eyes of 5 patients underwent EndoArt implantation. Six months after surgery, the synthetic endothelial replacement membrane was well-centered and adherent to the posterior corneal surface, with improvement in central corneal transparency in all patients. Corrected distance visual acuity increased from mean 1.26 ± 0.25 (logMAR) preoperatively to 0.74 ± 0.44 (logMAR) postoperatively (P = 0.06). Central corneal thickness significantly decreased from a mean of 805 ± 135 μm (excluding the EK graft) preoperatively to 588 ± 60 μm (excluding the EndoArt) postoperatively (P = 0.015). No severe device-related complications developed after surgery, although most patients required more than 1 air–gas bubble injection to achieve complete implant adhesion. All patients experienced preoperative reduction in subjective ocular pain. Conclusions: Synthetic endothelial replacement membrane implantation improves central corneal transparency and visual acuity in patients with failed EK and guarded prognosis for repeat keratoplasty. No significant implant-related adverse events occurred after surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3