Evaluation of the German Version of the Keratoconus Outcomes Research Questionnaire

Author:

Pomberger Leon12ORCID,Tasch Lisa12,Lundström Mats3,Waser Klemens12,Khalil Haidar12,Kronschläger Martin4,Hirnschall Nino12,Bolz Matthias12

Affiliation:

1. Department of Ophthalmology, Kepler University Clinic, Linz, Austria;

2. Department of Ophthalmology, Johannes Kepler University, Linz, Austria;

3. Department of Ophthalmology, Lund University, Lund, Sweden; and

4. Department of Ophthalmology, Mein Hanusch-Krankenhaus, Vienna, Austria.

Abstract

Purpose: To translate, validate, and evaluate the psychometric properties of the German version of Keratoconus Outcomes Research Questionnaire (KORQ). Methods: This prospective study included 3 phases. In phase 1, the KORQ was translated in a standardized way; in phase 2, Rasch validation was performed; in phase 3, the validated questionnaire was evaluated in a separate patient cohort. All patients answered the German KORQ. Scheimpflug imaging (Pentacam) and optical coherence tomography scans (MS-39) were conducted. Corneal imaging measurements were correlated with patient-reported outcome measures. Results: After standardized translation, 100 patients self-administered the German KORQ. Rasch analysis was conducted for psychometric testing of the KORQ. Based on the results of the Rasch analysis, the original German version of the KORQ was modified and any items showing a misfit were excluded. This resulted in a new shortened version of the KORQ, which was evaluated in 30 patients. The revised German KORQ met the criteria of Rasch analysis and showed excellent internal consistency reliability and convergent validity. The correlation between the KORQ score and various clinical measurements was examined using Spearman correlation. A significant moderate correlation was observed between the D (r = 0.237; P = 0.006) and Kmax (r = 0.162; P = 0.065) values of Pentacam. Inverse correlations were observed for thinnest pachymetry measured with MS-39 (r = −0.167; P = 0.058) and best corrected visual acuity (r = −0.210; P = 0.016). Conclusions: The shortened German KORQ met the assumptions of the Rasch model and displayed satisfactory psychometric properties. The German KORQ could be adopted as a powerful patient-reported outcome measures tool for German-speaking patients with keratoconus in the future.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3