Mediators of Visual Acuity in Descemet Membrane Endothelial Keratoplasty and Ultrathin Descemet Stripping Automated Endothelial Keratoplasty

Author:

Lin Charles C.1ORCID,Chamberlain Winston D.2,Kakigi Caitlin2,Arnold Benjamin F.3,Rose-Nussbaumer Jennifer13ORCID

Affiliation:

1. Byers Eye Institute, Stanford University, Palo Alto, CA;

2. Department of Ophthalmology, Casey Eye Institute, Oregon Health and Science University, Portland, OR; and

3. Francis I. Proctor Foundation, University of California San Francisco, San Francisco, CA.

Abstract

Purpose: The aim of this study was to investigate mediators of visual acuity in ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) compared with Descemet membrane endothelial keratoplasty (DMEK). Methods: This was a prespecified secondary analysis of the Descemet Endothelial Thickness Comparison Trial, a prospective, randomized controlled trial comparing UT-DSAEK with DMEK. Subjects with Fuchs endothelial dystrophy or pseudophakic bullous keratopathy presenting to 2 academic centers were enrolled and randomized to either UT-DSAEK (n = 25 eyes) or DMEK (n = 25 eyes). Higher order aberrations (HOAs) and corneal densitometry were measured with Pentacam Scheimpflug imaging at 3, 6, 12, and 24 months. Results: The posterior corneal surface at the 6.0-mm optical zone had significantly less total HOAs (P <0.001) in the DMEK group compared with UT-DSAEK at 24 months. Anterior and posterior corneal densitometry improved from baseline to 24 months for both UT-DSAEK and DMEK, but there was no significant difference between the 2 groups. Corneal densitometry and posterior HOAs were both associated with best-corrected visual acuity (P <0.05). DMEK had 1.3 logarithm of the minimum angle of resolution better visual acuity compared with UT-DSAEK at 24 months. Approximately 64% of this effect was mediated through posterior HOAs, whereas none was mediated through anterior HOAs or densitometry. Conclusions: Decreased posterior HOAs mediate better visual acuity and account for improved vision after DMEK compared with UT-DSAEK. Corneal light scatter as measured by densitometry is similar between UT-DSAEK and DMEK, indicating that the increased thickness and stromal–stromal interface in UT-DSAEK do not significantly affect visual acuity.

Funder

National Eye Institute

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3