Evaluation of Biomechanical Changes After Accelerated Cross-Linking in Progressive Keratoconus: A Prospective Follow-Up Study

Author:

Herber Robert1,Francis Mathew2,Spoerl Eberhard1,Pillunat Lutz E.1,Raiskup Frederik1,Roy Abhijit Sinha2

Affiliation:

1. Department of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden, Germany; and

2. Imaging, Biomechanics and Mathematical Modeling Solutions Lab, Narayana Nethralaya Foundation, Bangalore, India.

Abstract

Purpose: The aim of this study was to analyze the biomechanical effect of accelerated corneal cross-linking (9*10) in progressive keratoconus (KC) in comparison to untreated fellow eyes using Scheimpflug-based tonometry (Corvis ST, CVS). Methods: Forty-three eyes of 43 patients with KC showed progressive KC and were treated using accelerated corneal cross-linking. Twenty-five untreated fellow eyes were used as the control group. All eyes were examined biomechanically (CVS) and tomographically (Pentacam) at baseline, after 1-month, 6-month, and 12-month follow-up. Statistical analysis was performed using a linear mixed model. A logistic regression was performed to attribute the effects of changes in each parameter to treatment status (treated or untreated). Results: Maximum keratometry values decreased statistically significantly at 12 months by −1.1 D (95 confidence interval: −2.0 to −0.1, P = 0.025) compared with baseline. Thinnest corneal thickness decreased significantly after 1 month (P < 0.001) and recovered to baseline after 12 months (P = 0.752). In the corneal cross-linking (CXL) group, biomechanical changes were observed by an increased bIOP, a shorter A2 time, and a lower integrated radius after 1 month (all P < 0.05). No biomechanical and tomographical changes were observed in the control group (all P > 0.05). Logistic regression pointed out that treated eyes can be separated from untreated eyes by differences in bIOP, corneal thickness, A1 velocity, integrated radius, and Kc mean at 1, 6, and 12 months. Conclusions: The alterations in biomechanical parameters indicated a corneal stiffening effect after CXL treatment, which was mostly detectable 1 month after treatment, although corneal thickness was reduced. The logistic regression model showed an adequate separation between CXL-treated and untreated eyes.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3