Long-Term Safety and Efficacy of Perfluorohexyloctane Ophthalmic Solution for the Treatment of Patients With Dry Eye Disease: The KALAHARI Study

Author:

Protzko Eugene E.1,Segal Bruce A.2,Korenfeld Michael S.3,Krösser Sonja4,Vittitow Jason L.5

Affiliation:

1. Seidenberg Protzko Eye Associates, Havre de Grace, MD;

2. Private Practice, Delray Beach, FL;

3. Comprehensive Eye Care, Ltd, Washington, MO;

4. Novaliq GmbH, Heidelberg, Germany; and

5. Clinical Affairs, Bausch + Lomb, Bridgewater, NJ.

Abstract

Purpose: The aim of this study was to assess the long-term safety and efficacy of perfluorohexyloctane (PFHO) ophthalmic drop (formerly NOV03) for treatment of dry eye disease (DED). Methods: KALAHARI was a phase 3, multicenter, single-arm, open-label extension study in patients aged 18 years or older with DED associated with Meibomian gland dysfunction who completed the randomized, double-masked, hypotonic saline-controlled GOBI study. Patients instilled 1 drop of PFHO (MIEBO, Bausch + Lomb) 4 times daily in both eyes for 52 weeks. Safety assessments included adverse events, best-corrected visual acuity, slit-lamp biomicroscopy, intraocular pressure, and dilated fundoscopy. Efficacy end points included change from GOBI study baseline in total corneal fluorescein staining and eye dryness score (0–100 visual analog scale). Results: Overall, 208 patients from GOBI (PFHO [n = 97]; saline [n = 111]) were rolled over into KALAHARI. Twenty-nine patients (13.9%) had ≥1 ocular adverse event, with most being mild or moderate in severity; the most common ocular adverse events were vitreous detachment (1.9%), allergic conjunctivitis (1.4%), blurred vision (1.4%), and increased lacrimation (1.4%). Other safety end points were unremarkable. For patients continuing PFHO from GOBI, improvements in total corneal fluorescein staining and visual analog scale dryness scores observed in GOBI were maintained throughout KALAHARI. Patients treated with saline in GOBI and switched to PFHO in KALAHARI showed improvements in total corneal fluorescein staining and visual analog scale scores by week 4 that were maintained for the rest of the study. Conclusions: PFHO was safe and well tolerated and maintained efficacy for improving signs and symptoms of DED in this year-long study of patients with DED associated with Meibomian gland dysfunction.

Funder

Bausch + Lomb

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3