Assessment of the Corneal Biomechanical Features of Sturge–Weber Syndrome Using Dynamic Ultrahigh-speed Scheimpflug Imaging

Author:

Xie Mengzhen123ORCID,Tang Jing1ORCID,Zhang Yao12,Deng Yingping1,Ma Ke1,Xiang Xingye45,Tang Li1

Affiliation:

1. Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, China;

2. West China School of Medicine, Sichuan University, Chengdu, Sichuan, China;

3. Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China;

4. School of Life Science and Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China; and

5. Georgia State University, Atlanta, GA.

Abstract

Purpose: To evaluate the corneal biomechanical characteristics of eyes with Sturge–Weber syndrome (SWS) secondary glaucoma (SSG) by analyzing corneal biomechanical parameters obtained using the Corneal Visualization Scheimpflug Technology instrument (Corvis ST). Methods: In patients with SWS, eyes affected by SSG were designated as the SSG group while the contralateral eyes were designated as the SWS contralateral group (SC group). Patients from the myopia clinic served as the control group. Dynamic corneal response parameters (DCRs) including the stress–strain index (SSI)—a critical material stiffness parameter that excludes interference from IOP and central corneal thickness (CCT)—were analyzed. Results: For CCT, no significant difference was observed between the SSG and SC groups. However, significant differences were found between the SSG and control groups and between the SC and control groups. Parameters such as HC Time, A1 Deformation Amp., A2 Deformation Amp., length of Whole Eye Movement (WEM), DA Ratio Max (2 mm), PachySlope, DA Ratio Max (1 mm), and ARTh showed significant differences between the SSG group and control group. In the SSG group, 4 of night eyes had an SSI of less than 0.85. Conclusions: Some DCRs indicated a stiffer cornea in the SSG group, possibly due to a thicker cornea in this group. On analyzing SSI, it was found that corneal material properties change, becoming less stiff in some of the patients with SSG. In conclusion, our study provides a preliminary exploration of the biomechanical properties of SWS secondary glaucoma.

Funder

West China Hospital, Sichuan University

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3