Abstract

Background and Objective: Artificial total joint replacement is an important method of temporomandibular joint (TMJ) reconstruction, which has been advocated for TMJ osteoarthrosis, ankylosis, tumors, and other diseases. We designed one type of standard TMJ prosthesis fit for Chinese patients. This study aimed to explore the biomechanical behavior of the standard TMJ prosthesis using finite element analysis and selects an optimal screw arrangement scheme for clinical application. Materials and Methods: A female volunteer was recruited for a maxillofacial computed tomography scan, then the Hypermesh software was used to establish a finite element model of a mandibular condyle defect repaired with an artificial TMJ prosthesis. An advanced universal finite element program software was used to calculate the stress and deformation under a simulated maximum bite force loading. Also, the forces of screws under different numbers and arrangements were analyzed. Meanwhile, we designed an experiment to verify the calculation model. Results: The average maximum stress of the fossa component of the standard prosthesis model was 19.25 MPa. The average maximum stress of the condyle component was 82.58 MPa, mainly concentrated near the top row hole. The fossa component should be fixed with at least 3 screws, and the optimal number of screws was 4. The condyle component should be fixed with at least 4 screws, and its optimal number was 6. The best scheme of screw arrangement was determined. The results of the verification experiment showed that the analysis was reliable. Conclusions: The stress distribution of the standard TMJ prosthesis is uniform, meanwhile, the number and arrangement of the screws significantly affect the contact force of the screws.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine,Otorhinolaryngology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3