Polyether Ether Ketone (PEEK) Implants and the Manufacturer and User Facility Device Experience (MAUDE) Database: An Updated Review of Adverse Events and Complications

Author:

Shewmake Connor1,Khetpal Sumun2,Ozaki Wayne23

Affiliation:

1. College of Medicine, University of Arkansas for Medical Sciences, Little Rock, AR

2. Division of Plastic and Reconstructive Surgery, University of California—Los Angeles

3. Section of Oral & Maxillofacial Surgery, University of California—Los Angeles, Los Angeles, CA

Abstract

Introduction: Polyether ether ketone (PEEK) custom implants have been fundamental in addressing bone malformations and restoring traumatic defects within the field of craniofacial surgery. Although such implants are generally considered safe and appropriate alternatives to autologous bone grafts, there has been a lack of standardized reporting of adverse events associated with PEEK implants. The purpose of this study is multi-fold: (1) to explore the current landscape of autologous and allogeneic materials utilized for bone grafting; (2) to analyze and characterize adverse events associated within PEEK implants from the widely accredited, FDA-run database, Manufacturer and User Facility Device Experience (MAUDE); and using the data, (3) to provide guidance to craniofacial surgeons using PEEK implants in their surgical practice. Material/Methods: A retrospective review of the adverse events associated with PEEK implants were performed through the FDA-run database, Manufacturer and User Facility Device Experience (MAUDE). The database was surveyed from July 2013 to January 2023. Event types were categorized by injury or malfunction, and device-reported adverse events were recorded, respectively. Results: Database search initially yielded 77 adverse event reports, but after duplicates were removed, 69 event reports were included in the analysis. These events were sorted into the following categories: device-related and patient-related. Event types were categorized by injury (48.3%) or malfunction (53.6%). The most common reported device-related adverse events were “Poor Fit” (53.6%) and “Adverse Event without Identified Use or Problem “ (26.1%). The most common reported patient-related event was “Infection” (32.8%). Of these adverse event reports, 14 (20.2%) patients required a second surgery; 21(30.4%) required implant modification whereas in the operating room; 17 (24.6%) underwent implant removal. Nine (13%) patients experienced operative case delays due to implant modifications. Conclusion: Infection and poor fit were among the most commonly reported adverse events associated with PEEK customizable implants. Although PEEK implants have been widely implemented in addressing craniofacial bony defects, our database analysis does call for further investigation in studying the long-term outcomes associated with PEEK craniofacial implants. With such analyses and collaboration among plastic surgeons and device engineers, there is great opportunity for innovation of these devices.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine,Otorhinolaryngology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3