Clinical Experience in Minimally Invasive Cardiac Surgery with Virtually Wall-Less Venous Cannulas

Author:

Ferrari Enrico1,von Segesser Ludwig K.2,Berdajs Denis3,Müller Ludwig4,Halbe Maximilian5,Maisano Francesco5

Affiliation:

1. CardioCentro Ticino Foundation, Lugano, Switzerland

2. CHUV Lausanne, Switzerland

3. University Hospital, Basel, Switzerland

4. University Hospital, Innsbruck, Austria

5. University Hospital, Zurich, Switzerland.

Abstract

Objective Inadequate peripheral venous drainage during minimally invasive cardiac surgery (MICS) is a challenge and cannot always be solved with increased vacuum or increased centrifugal pump speed. The present study was designed to assess the benefit of virtually wall-less transfemoral venous cannulas during MICS. Methods Transfemoral venous cannulation with virtually wall-less cannulas (3/8″ 24F 530–630-mm ST) was performed in 10 consecutive patients (59 ± 10 years, 8 males, 2 females) undergoing MICS for mitral (6), aortic (3), and other (4) procedures (combinations possible). Before transfemoral insertion of wall-less cannulas, a guidewire was positioned in the superior vena cava under echocardiographic control. The wall-less cannula was then fed over the wire and connected to a minimal extracorporeal system. Vacuum assist was used to reach a target flow of 2.4 l/min per m2 with augmented venous drainage at less than −80 mm Hg. Results Wall-less venous cannulas measuring either 630 mm (n = 8) in length or 530 mm (n = 2) were successfully implanted in all patients. For a body size of 173 ± 11 cm and a body weight of 78 ± 26 kg, the calculated body surface area was 1.94 ± 0.32 m2. As a result, the estimated target flow was 4.66 ± 0.78 l/min, whereas the achieved flow accounted for 4.98 ± 0.69 l/min (107% of target) at a vacuum level of 21.3 ± 16.4 mm Hg. Excellent exposure and “dry” intracardiac surgical field resulted. Conclusions The performance of virtually wall-less venous cannulas designed for augmented peripheral venous drainage was tested in MICS and provided excellent flows at minimal vacuum levels, confirming an increased performance over traditional thin wall cannulas. Superior results can be expected for routine use.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3